Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2007 |
Principal Product | PVC fence, deck, railing, irrigation pipe & fittings |
NAICS | 326199 - All Other Plastics Product Manufacturing |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 133 |
Plant Area (Sq.Ft.) | 39,710 |
Annual Production | 24,600,000 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | NE |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $155,796 | 6,010,089 | kWh | $0.03 |
Electricity Demand | $94,389 | 12,949 | kW-months/year | $7.29 |
Electricity Fees | $600 | - | $ | - |
Natural Gas | $22,736 | 18,848 | MMBtu | $1.21 |
TOTAL ENERGY COSTS | $273,521 | |||
RECOMMENDED SAVINGS* | $10,124 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,910 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $534 Cost: $1,998 |
$354 | 13,718 | $180 | 25 | - | - | - | - |
$354 13,718 kWh |
$180 25 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,550 Cost: $730 |
$1,120 | 43,100 | $430 | 59 | - | - | - | - |
$1,120 43,100 kWh |
$430 59 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $230 Cost: $460 |
$160 | 6,300 | $70 | 9 | - | - | - | - |
$160 6,300 kWh |
$70 9 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,790 Cost: $10,600 |
$1,960 | 76,100 | $840 | 116 | $130 | - | $860 | - |
$1,960 76,100 kWh |
$840 116 kW-months/year |
$130 - $ |
$860 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,680 Cost: $11,760 |
$2,140 | 82,700 | $860 | 119 | $80 | - | $600 | - |
$2,140 82,700 kWh |
$860 119 kW-months/year |
$80 - $ |
$600 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $340 Cost: $540 |
$50 | 1,800 | $10 | 2 | $60 | - | $220 | - |
$50 1,800 kWh |
$10 2 kW-months/year |
$60 - $ |
$220 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $10,124 Cost: $26,088 |
$5,784 | 223,718 | $2,390 | 330 | $270 | - | $1,680 | - | $5,784 223,718 kWh |
$2,390 330 kW-months/year |
$270 - $ |
$1,680 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,910 Cost: $12,330 |
$3,290 | 127,300 | $1,350 | 186 | $190 | - | $1,080 | - | $3,290 127,300 kWh |
$1,350 186 kW-months/year |
$190 - $ |
$1,080 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost |