Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2007 |
Principal Product | Wood Doors & Architectural Millwork |
NAICS | 321911 - Wood Window and Door Manufacturing |
SIC | 2431 - Millwork |
Sales | $10,000,000-$50,000,000 |
# of Employees | 120 |
Plant Area (Sq.Ft.) | 70,000 |
Annual Production | 18,000 Pieces |
Production Hrs. Annual | 4,680 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $50,364 | 1,496,960 | kWh | $0.03 |
Electricity Demand | $76,273 | 5,359 | kW-months/year | $14.23 |
Electricity Fees | $322 | - | $ | - |
Natural Gas | $8,146 | 1,000 | MMBtu | $8.15 |
Fuel Oil #2 | $88,400 | 4,267 | MMBtu | $20.72 |
TOTAL ENERGY COSTS | $223,505 | |||
RECOMMENDED SAVINGS* | $25,267 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $4,797 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #2 | Ancillary Material Cost | Electricity Usage | Electricity Demand | Fuel Oil #2 | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $12,270 Cost: $89,570 |
$4,680 | 195,100 | $7,590 | 500 | - | - | - | - |
$4,680 195,100 kWh |
$7,590 500 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,220 Cost: $610 |
$1,720 | 71,900 | $1,500 | 99 | - | - | - | - |
$1,720 71,900 kWh |
$1,500 99 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $1,460 Cost: - |
$1,460 | 60,900 | - | - | - | - | - | - |
$1,460 60,900 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,220 Cost: $3,430 |
$660 | 27,300 | $560 | 37 | - | - | - | - |
$660 27,300 kWh |
$560 37 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $117 Cost: $276 |
$45 | 1,863 | $72 | 5 | - | - | - | - |
$45 1,863 kWh |
$72 5 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.8226 INCREASE EFFICIENCY OF TRUCKS |
Savings: $5,040 Cost: - |
- | - | - | - | $5,040 | 1,524 | - | - |
- - kWh |
- - kW-months/year |
$5,040 1,524 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $1,290 Cost: $11,000 |
$350 | 14,600 | $940 | 62 | - | - | - | - |
$350 14,600 kWh |
$940 62 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $600 Cost: $2,270 |
$150 | 6,100 | $470 | 31 | - | - | $(-20) | - |
$150 6,100 kWh |
$470 31 kW-months/year |
- - MMBtu |
$(-20) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $50 Cost: $200 |
$30 | 1,200 | $20 | 1 | - | - | - | - |
$30 1,200 kWh |
$20 1 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $25,267 Cost: $107,356 |
$9,095 | 378,963 | $11,152 | 735 | $5,040 | 1,524 | $(-20) | - | $9,095 378,963 kWh |
$11,152 735 kW-months/year |
$5,040 1,524 MMBtu |
$(-20) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $4,797 Cost: $886 |
$3,225 | 134,663 | $1,572 | 104 | - | - | - | - | $3,225 134,663 kWh |
$1,572 104 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Fuel Oil #2 | Ancillary Material Cost | Electricity Usage | Electricity Demand | Fuel Oil #2 | Ancillary Material Cost |