Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2008 |
Principal Product | Kitchen & bathroom cabinets |
NAICS | 337110 - Wood Kitchen Cabinet and Countertop Manufacturing |
SIC | 2434 - Wood Kitchen Cabinets |
Sales | $10,000,000-$50,000,000 |
# of Employees | 161 |
Plant Area (Sq.Ft.) | 199,000 |
Annual Production | 125,000 Pieces |
Production Hrs. Annual | 2,860 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $70,779 | 2,154,555 | kWh | $0.03 |
Electricity Demand | $143,624 | 8,761 | kW-months/year | $16.39 |
Electricity Fees | $384 | - | $ | - |
Natural Gas | $85,222 | 10,160 | MMBtu | $8.39 |
TOTAL ENERGY COSTS | $300,009 | |||
RECOMMENDED SAVINGS* | $38,700 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,080 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $13,590 Cost: $59,400 |
$1,150 | 31,100 | $5,990 | 367 | - | - | - | - | $6,450 | - |
$1,150 31,100 kWh |
$5,990 367 kW-months/year |
- - MMBtu |
- - $ |
$6,450 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,920 Cost: $300 |
$1,280 | 34,600 | $640 | 38 | - | - | - | - | - | - |
$1,280 34,600 kWh |
$640 38 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4235 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES |
Savings: $160 Cost: $450 |
$160 | 4,200 | - | - | - | - | - | - | - | - |
$160 4,200 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $14,400 Cost: $25,650 |
$5,490 | 148,100 | $8,910 | 526 | - | - | - | - | - | - |
$5,490 148,100 kWh |
$8,910 526 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $5,270 Cost: $10,430 |
$1,720 | 46,300 | $3,290 | 194 | - | - | $180 | - | $80 | - |
$1,720 46,300 kWh |
$3,290 194 kW-months/year |
- - MMBtu |
$180 - $ |
$80 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $1,930 Cost: $15,400 |
$(-460) | (-12,300) | $(-290) | (-17) | $2,680 | 316 | - | - | - | - |
$(-460) (-12,300) kWh |
$(-290) (-17) kW-months/year |
$2,680 316 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $1,430 Cost: $960 |
- | - | - | - | $1,430 | 168 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,430 168 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $38,700 Cost: $112,590 |
$9,340 | 252,000 | $18,540 | 1,108 | $4,110 | 484 | $180 | - | $6,530 | - | $9,340 252,000 kWh |
$18,540 1,108 kW-months/year |
$4,110 484 MMBtu |
$180 - $ |
$6,530 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,080 Cost: $750 |
$1,440 | 38,800 | $640 | 38 | - | - | - | - | - | - | $1,440 38,800 kWh |
$640 38 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |