IAC logo
IAC Assessment: CO0618
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: CO0618
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 2008
Principal Product Jewelry and jewelry-making equipment
NAICS 339910 - Jewelry and Silverware Manufacturing
SIC 3911 - Jewelry, Precious Metal
Sales $100,000,000-$500,000,000
# of Employees 390
Plant Area (Sq.Ft.) 187,500
Annual Production 1,040,000 Pieces
Production Hrs. Annual 3,120
Location (State) NM
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $129,755 2,838,700 kWh $0.05
Electricity Demand $63,149 10,734 kW-months/year $5.88
Electricity Fees $78,803 - $ -
Natural Gas $28,894 2,779 MMBtu $10.40
TOTAL ENERGY COSTS $300,601
RECOMMENDED SAVINGS* $44,720 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $29,670
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes Administrative Changes Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Personnel Changes Administrative Changes Ancillary Material Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $ $ $
01: 2.3137 USE POWER DURING OFF-PEAK PERIODS Savings:
$15,050
Cost:
-
$15,050 266,600 - - - - - - - - - - $15,050
266,600
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
$
02: 2.6242 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION Savings:
$19,720
Cost:
$10,000
$19,720 478,700 - - - - - - - - - - $19,720
478,700
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
$
03: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$5,170
Cost:
$61,600
$1,270 21,800 $1,070 80 - - - - $2,830 - - - $1,270
21,800
kWh
$1,070
80
kW-months/year
-
-
MMBtu
-
-
$
$2,830
-
$
-
-
$
04: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$1,950
Cost:
$42,300
$(-1,350) (-28,900) $(-520) (-39) $3,820 339 - - - - - - $(-1,350)
(-28,900)
kWh
$(-520)
(-39)
kW-months/year
$3,820
339
MMBtu
-
-
$
-
-
$
-
-
$
05: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,780
Cost:
$50,000
$790 13,500 $770 58 - - $10 - - - $210 - $790
13,500
kWh
$770
58
kW-months/year
-
-
MMBtu
$10
-
$
-
-
$
$210
-
$
06: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$1,050
Cost:
$640
$410 7,000 $530 40 - - - - - - $110 - $410
7,000
kWh
$530
40
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
$110
-
$
TOTAL RECOMMENDED Savings:
$44,720
Cost:
$164,540
$35,890 758,700 $1,850 139 $3,820 339 $10 - $2,830 - $320 - $35,890
758,700
kWh
$1,850
139
kW-months/year
$3,820
339
MMBtu
$10
-
$
$2,830
-
$
$320
-
$
TOTAL IMPLEMENTED Savings:
$29,670
Cost:
$164,540
$20,840 492,100 $1,850 139 $3,820 339 $10 - $2,830 - $320 - $20,840
492,100
kWh
$1,850
139
kW-months/year
$3,820
339
MMBtu
$10
-
$
$2,830
-
$
$320
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $ $ $
Electricity Usage Electricity Demand Natural Gas Personnel Changes Administrative Changes Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Personnel Changes Administrative Changes Ancillary Material Cost