Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 2009
Principal Product Analytical Instruments
NAICS 334516 - Analytical Laboratory Instrument Manufacturing
SIC 3826 - Analytical Instruments
Sales $10,000,000-$50,000,000
# of Employees 70
Plant Area (Sq.Ft.) 130,000
Annual Production 17,000 Pieces
Production Hrs. Annual 6,240
Location (State) CO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $56,972 1,304,000 kWh $0.04
Electricity Demand $54,260 3,316 kW-months/year $16.36
Electricity Fees $371 - $ -
Natural Gas $45,995 5,658 MMBtu $8.13
TOTAL ENERGY COSTS $157,598
RECOMMENDED SAVINGS* $20,820 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Personnel Changes Ancillary Material Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,370
Cost:
$3,610
$800 21,300 $570 29 - - - - - - $800
21,300
kWh
$570
29
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$15,440
Cost:
$26,850
$6,680 178,200 $8,740 451 - - $40 - $(-20) - $6,680
178,200
kWh
$8,740
451
kW-months/year
-
-
MMBtu
$40
-
$
$(-20)
-
$
03: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$1,750
Cost:
$10,500
$550 14,600 $1,200 62 - - - - - - $550
14,600
kWh
$1,200
62
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
04: 2.9112 USE SOLAR HEAT TO HEAT WATER Savings:
$1,750
Cost:
$11,200
- - - - $1,750 328 - - - - -
-
kWh
-
-
kW-months/year
$1,750
328
MMBtu
-
-
$
-
-
$
05: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$510
Cost:
$5,340
$(-140) (-3,700) $(-100) (-5) $750 140 - - - - $(-140)
(-3,700)
kWh
$(-100)
(-5)
kW-months/year
$750
140
MMBtu
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$20,820
Cost:
$57,500
$7,890 210,400 $10,410 537 $2,500 468 $40 - $(-20) - $7,890
210,400
kWh
$10,410
537
kW-months/year
$2,500
468
MMBtu
$40
-
$
$(-20)
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $