Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2010 |
Principal Product | Motor oil |
NAICS | 324191 - Petroleum Lubricating Oil and Grease Manufacturing |
SIC | 2992 - Lubricating Oils And Greases |
Sales | $10,000,000-$50,000,000 |
# of Employees | 32 |
Plant Area (Sq.Ft.) | 197,400 |
Annual Production | 520,000 Pieces |
Production Hrs. Annual | 5,460 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $45,338 | 1,052,928 | kWh | $0.04 |
Electricity Demand | $49,727 | 2,999 | kW-months/year | $16.58 |
Electricity Fees | $3,147 | - | $ | - |
Natural Gas | $25,982 | 3,155 | MMBtu | $8.24 |
TOTAL ENERGY COSTS | $124,194 | |||
RECOMMENDED SAVINGS* | $20,630 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $20,630 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,000 Cost: $19,665 |
$230 | 6,300 | $770 | 47 | - | - | - | - |
$230 6,300 kWh |
$770 47 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $12,360 Cost: $3,977 |
$5,070 | 132,700 | $6,930 | 401 | $150 | - | $210 | - |
$5,070 132,700 kWh |
$6,930 401 kW-months/year |
$150 - $ |
$210 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,020 Cost: $5,662 |
$590 | 15,900 | $1,190 | 72 | $30 | - | $210 | - |
$590 15,900 kWh |
$1,190 72 kW-months/year |
$30 - $ |
$210 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $1,920 Cost: $27,104 |
$560 | 14,600 | $1,360 | 77 | - | - | - | - |
$560 14,600 kWh |
$1,360 77 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,710 Cost: $8,757 |
$640 | 17,500 | $1,140 | 69 | $30 | - | $(-100) | - |
$640 17,500 kWh |
$1,140 69 kW-months/year |
$30 - $ |
$(-100) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,020 Cost: $37,620 |
$110 | 3,000 | $70 | 4 | $380 | - | $460 | - |
$110 3,000 kWh |
$70 4 kW-months/year |
$380 - $ |
$460 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $600 Cost: $3,108 |
$140 | 3,900 | $250 | 15 | $40 | - | $170 | - |
$140 3,900 kWh |
$250 15 kW-months/year |
$40 - $ |
$170 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $20,630 Cost: $105,893 |
$7,340 | 193,900 | $11,710 | 685 | $630 | - | $950 | - | $7,340 193,900 kWh |
$11,710 685 kW-months/year |
$630 - $ |
$950 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $20,630 Cost: $105,893 |
$7,340 | 193,900 | $11,710 | 685 | $630 | - | $950 | - | $7,340 193,900 kWh |
$11,710 685 kW-months/year |
$630 - $ |
$950 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost |