Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2013 |
Principal Product | Pumps and compressors |
NAICS | 333911 - Pump and Pumping Equipment Manufacturing |
SIC | 3561 - Pumps And Pumping Equipment |
Sales | $100,000,000-$500,000,000 |
# of Employees | 429 |
Plant Area (Sq.Ft.) | 191,000 |
Annual Production | 4,200 Pieces |
Production Hrs. Annual | 8,760 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $289,934 | 7,588,875 | kWh | $0.04 |
Electricity Demand | $459,742 | 25,945 | kW-months/year | $17.72 |
Electricity Fees | $15,758 | - | $ | - |
Natural Gas | $44,384 | 6,984 | MMBtu | $6.36 |
TOTAL ENERGY COSTS | $809,818 | |||
RECOMMENDED SAVINGS* | $50,100 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $47,980 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $21,220 Cost: $50,000 |
- | - | $21,220 | 1,200 | - | - | - | - | - | - |
- - kWh |
$21,220 1,200 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $2,950 Cost: $17,590 |
$1,760 | 49,800 | $1,190 | 68 | - | - | - | - | - | - |
$1,760 49,800 kWh |
$1,190 68 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,460 Cost: $11,450 |
$720 | 20,300 | $740 | 42 | - | - | - | - | - | - |
$720 20,300 kWh |
$740 42 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE |
Savings: $13,790 Cost: $35,250 |
$(-70) | (-1,900) | - | - | $13,860 | 3,118 | - | - | - | - |
$(-70) (-1,900) kWh |
- - kW-months/year |
$13,860 3,118 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE |
Savings: $2,370 Cost: $4,500 |
$960 | 27,100 | - | - | $1,410 | 317 | - | - | - | - |
$960 27,100 kWh |
- - kW-months/year |
$1,410 317 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $2,120 Cost: $15,820 |
$1,200 | 33,800 | $920 | 52 | - | - | - | - | - | - |
$1,200 33,800 kWh |
$920 52 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $6,190 Cost: $15,000 |
$5,330 | 150,500 | - | - | - | - | $320 | - | $540 | - |
$5,330 150,500 kWh |
- - kW-months/year |
- - MMBtu |
$320 - $ |
$540 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $50,100 Cost: $149,610 |
$9,900 | 279,600 | $24,070 | 1,362 | $15,270 | 3,435 | $320 | - | $540 | - | $9,900 279,600 kWh |
$24,070 1,362 kW-months/year |
$15,270 3,435 MMBtu |
$320 - $ |
$540 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $47,980 Cost: $133,790 |
$8,700 | 245,800 | $23,150 | 1,310 | $15,270 | 3,435 | $320 | - | $540 | - | $8,700 245,800 kWh |
$23,150 1,310 kW-months/year |
$15,270 3,435 MMBtu |
$320 - $ |
$540 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |