Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2022 |
Principal Product | Plastic biomedical components |
NAICS | 326122 - Plastics Pipe and Pipe Fitting Manufacturing |
SIC | 3089 - Plastics Products, Nec |
Sales | $5,000,000-$10,000,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 13,120 |
Annual Production | 120,000,000 Pieces |
Production Hrs. Annual | 8,592 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $62,489 | 769,216 | kWh | $0.08 |
Electricity Demand | $17,306 | 1,051 | kW-months/year | $16.47 |
Electricity Fees | $3,861 | - | $ | - |
Natural Gas | $6,220 | 647 | MMBtu | $9.61 |
TOTAL ENERGY COSTS | $89,876 | |||
RECOMMENDED SAVINGS* | $304,985 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $26,159 Cost: $136,687 |
$16,642 | 208,291 | $1,706 | 89 | - | - | $7,811 | - | - | - |
$16,642 208,291 kWh |
$1,706 89 kW-months/year |
- - MMBtu |
$7,811 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $881 Cost: $2,407 |
- | - | - | - | $881 | 92 | - | - | - | - |
- - kWh |
- - kW-months/year |
$881 92 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $2,175 Cost: $7,076 |
$2,175 | 18,633 | - | - | - | - | - | - | - | - |
$2,175 18,633 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $1,847 Cost: $9,768 |
$1,595 | 16,044 | $252 | 13 | - | - | - | - | - | - |
$1,595 16,044 kWh |
$252 13 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3192 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS |
Savings: $210,000 Cost: $58,000 |
- | - | - | - | - | - | - | - | $210,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$210,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3513 CONSIDER POWER LOSS AS WELL AS INITIAL LOADS AND LOAD GROWTH IN DOWN-SIZING TRANSFORMERS |
Savings: $60,192 Cost: $4,219 |
$132 | 1,657 | - | - | - | - | - | - | $60,060 | - |
$132 1,657 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$60,060 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,731 Cost: $3,276 |
$3,248 | 31,511 | $483 | 25 | - | - | - | - | - | - |
$3,248 31,511 kWh |
$483 25 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $304,985 Cost: $221,433 |
$23,792 | 276,136 | $2,441 | 127 | $881 | 92 | $7,811 | - | $270,060 | - | $23,792 276,136 kWh |
$2,441 127 kW-months/year |
$881 92 MMBtu |
$7,811 - $ |
$270,060 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Primary Product |