Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Case Western Reserve University |
---|---|
Assessment Year | 2022 |
Principal Product | Frozen buns |
NAICS | 493120 - Refrigerated Warehousing and Storage |
SIC | 4222 - Refrigerated Warehousing And Storage |
Sales | >$500,000,000 |
# of Employees | 215 |
Plant Area (Sq.Ft.) | 158,000 |
Annual Production | 15,000,000 Pieces |
Production Hrs. Annual | 8,640 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $273,391 | 4,231,929 | kWh | $0.06 |
Electricity Demand | $54,335 | 8,064 | kW-months/year | $6.74 |
Electricity Fees | $1,810 | - | $ | - |
Natural Gas | $21,126 | 3,237 | MMBtu | $6.53 |
TOTAL ENERGY COSTS | $369,060 | |||
RECOMMENDED SAVINGS* | $275,801 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Water Usage | Administrative Changes | Electricity Usage | Water Usage | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,407 Cost: $100 |
$1,407 | 21,991 | - | - | - | - |
$1,407 21,991 kWh |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $17,378 Cost: $47,373 |
$17,378 | 271,532 | - | - | - | - |
$17,378 271,532 kWh |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3142 USER BATTERY STORAGE FOR POWER QUALITY ISSUES |
Savings: $230,341 Cost: $287,555 |
- | - | - | - | $230,341 | - |
- - kWh |
- - Tgal |
$230,341 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.112 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL |
Savings: $7,380 Cost: - |
- | - | - | - | $7,380 | - |
- - kWh |
- - Tgal |
$7,380 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.426 MODIFY WORKLOAD |
Savings: $16,860 Cost: - |
$16,860 | 262,215 | - | - | - | - |
$16,860 262,215 kWh |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $929 Cost: $1,866 |
$929 | 14,509 | - | - | - | - |
$929 14,509 kWh |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.4159 REPLACE TREATED WATER WITH WELL / SURFACE WATER |
Savings: $1,505 Cost: $2,582 |
- | - | $1,667 | 405 | $(-162) | - |
- - kWh |
$1,667 405 Tgal |
$(-162) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $275,801 Cost: $339,476 |
$36,574 | 570,247 | $1,667 | 405 | $237,560 | - | $36,574 570,247 kWh |
$1,667 405 Tgal |
$237,560 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - - kWh |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Water Usage | Administrative Changes | Electricity Usage | Water Usage | Administrative Changes |