Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Case Western Reserve University
Assessment Year 2024
Principal Product Refurbishment of Battery Modules
NAICS 335999 - All Other Miscellaneous Electrical Equipment and Component Manufacturing
SIC 3699 - Electrical Equipment & Supplies, Nec
Sales $10,000,000-$50,000,000
# of Employees 168
Plant Area (Sq.Ft.) 114,880
Annual Production 10,000 Units
Production Hrs. Annual 2,080
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $71,624 1,527,158 kWh $0.05
Natural Gas $35,154 4,418 MMBtu $7.96
TOTAL ENERGY COSTS $106,778
RECOMMENDED SAVINGS* $35,255 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,562
Cost:
$17,397
$4,562 97,281 - - $4,562
97,281
kWh
-
-
MMBtu
02: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$4,196
Cost:
$2,050
$4,196 89,461 - - $4,196
89,461
kWh
-
-
MMBtu
03: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS Savings:
$17,298
Cost:
$8,391
- - $17,298 2,174 -
-
kWh
$17,298
2,174
MMBtu
04: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS Savings:
$202
Cost:
$424
- - $202 25 -
-
kWh
$202
25
MMBtu
05: 2.2531 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR Savings:
$7,210
Cost:
$13,000
$(-37) (-792) $7,247 911 $(-37)
(-792)
kWh
$7,247
911
MMBtu
06: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$1,786
Cost:
$6,750
$1,786 38,086 - - $1,786
38,086
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$35,255
Cost:
$48,012
$10,507 224,036 $24,748 3,110 $10,507
224,036
kWh
$24,748
3,110
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas