Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Delaware
Assessment Year 2009
Principal Product plumbing fixtures
NAICS 332913 - Plumbing Fixture Fitting and Trim Manufacturing
SIC 3432 - Plumbing Fixture Fittings And Trim
Sales $10,000,000-$50,000,000
# of Employees 114
Plant Area (Sq.Ft.) 65,000
Annual Production 96,000 Pieces
Production Hrs. Annual 3,120
Location (State) DE
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $105,827 663,920 kWh $0.16
Natural Gas $38 2,556 MMBtu $0.01
TOTAL ENERGY COSTS $105,865
RECOMMENDED SAVINGS* $21,444 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $9,724
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$9,690
Cost:
$18,300
- - - - $9,690 638 -
-
kWh
-
-
kW-months/year
$9,690
638
MMBtu
02: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$3,192
Cost:
-
- - - - $3,192 210 -
-
kWh
-
-
kW-months/year
$3,192
210
MMBtu
03: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$5,472
Cost:
$3,500
- - - - $5,472 360 -
-
kWh
-
-
kW-months/year
$5,472
360
MMBtu
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$600
Cost:
$950
- - - - $600 39 -
-
kWh
-
-
kW-months/year
$600
39
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$960
Cost:
$2,000
$960 6,440 - - - - $960
6,440
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$470
Cost:
$510
$470 3,150 - - - - $470
3,150
kWh
-
-
kW-months/year
-
-
MMBtu
07: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$1,060
Cost:
-
- - $1,060 11 - - -
-
kWh
$1,060
11
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$21,444
Cost:
$25,260
$1,430 9,590 $1,060 11 $18,954 1,247 $1,430
9,590
kWh
$1,060
11
kW-months/year
$18,954
1,247
MMBtu
TOTAL IMPLEMENTED Savings:
$9,724
Cost:
$3,500
- - $1,060 11 $8,664 570 -
-
kWh
$1,060
11
kW-months/year
$8,664
570
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu