IAC logo
IAC Assessment: DS0004
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: DS0004
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center South Dakota State
Assessment Year 1994
Principal Product Turkey Feed Pellets
NAICS n/a
SIC 2048 - Prepared Feeds, Nec
Sales $50,000,000-$100,000,000
# of Employees 125
Plant Area (Sq.Ft.) 65,600
Annual Production 375,000 Tons
Production Hrs. Annual 8,736
Location (State) MN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $300,310 6,241,501 kWh $0.05
Natural Gas $111,611 41,722 MMBtu $2.68
TOTAL ENERGY COSTS $411,921
RECOMMENDED SAVINGS* $208,663 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $12,702
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,193
Cost:
$1,791
$1,193 24,326 - - $1,193
24,326
kWh
-
-
MMBtu
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$7,387
Cost:
$20,751
$7,387 171,747 - - $7,387
171,747
kWh
-
-
MMBtu
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$415
Cost:
$144
$415 12,603 - - $415
12,603
kWh
-
-
MMBtu
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,246
Cost:
$3,479
$1,246 38,101 - - $1,246
38,101
kWh
-
-
MMBtu
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$1,636
Cost:
$400
$1,636 50,117 - - $1,636
50,117
kWh
-
-
MMBtu
06: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT Savings:
$184,881
Cost:
$2,000,000
$184,881 2,294,842 - - $184,881
2,294,842
kWh
-
-
MMBtu
07: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$2,120
Cost:
$553
- - $2,120 771 -
-
kWh
$2,120
771
MMBtu
08: 2.2511 INSULATE BARE EQUIPMENT Savings:
$1,573
Cost:
$520
- - $1,573 472 -
-
kWh
$1,573
472
MMBtu
09: 2.2711 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING Savings:
$8,212
Cost:
$16,424
$4,642 94,666 $3,570 1,298 $4,642
94,666
kWh
$3,570
1,298
MMBtu
TOTAL RECOMMENDED Savings:
$208,663
Cost:
$2,044,062
$201,400 2,686,402 $7,263 2,541 $201,400
2,686,402
kWh
$7,263
2,541
MMBtu
TOTAL IMPLEMENTED Savings:
$12,702
Cost:
$22,238
$9,132 219,813 $3,570 1,298 $9,132
219,813
kWh
$3,570
1,298
MMBtu
Savings
Cost
$ kWh $ MMBtu