Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | South Dakota State |
---|---|
Assessment Year | 1998 |
Principal Product | Canned and Frozen Peas and Corn |
NAICS | n/a |
SIC | 2033 - Canned Fruits And Vegetables |
Sales | $50,000,000-$100,000,000 |
# of Employees | 1,400 |
Plant Area (Sq.Ft.) | 467,083 |
Annual Production | 146,466,247 Pounds |
Production Hrs. Annual | 2,304 |
Location (State) | MN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $825,927 | 20,642,732 | kWh | $0.04 |
Electricity Demand | $264,685 | 41,040 | kW-months/year | $6.45 |
Electricity Fees | $42,608 | - | $ | - |
Natural Gas | $309,918 | 111,876 | MMBtu | $2.77 |
TOTAL ENERGY COSTS | $1,580,320 | |||
RECOMMENDED SAVINGS* | $74,767 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $34,934 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,385 Cost: $21,938 |
$3,464 | 101,993 | $921 | 336 | - | - | - | - | - | - |
$3,464 101,993 kWh |
$921 336 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $2,039 Cost: $2,213 |
- | - | $2,039 | 827 | - | - | - | - | - | - |
- - kWh |
$2,039 827 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $30,549 Cost: $25,900 |
- | - | - | - | $30,549 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$30,549 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $15,838 Cost: $30,000 |
- | - | - | - | - | - | $15,838 | 5,718 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$15,838 5,718 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.2176 INCREASE USE OF AUTOMATION |
Savings: $6,750 Cost: $10,000 |
- | - | - | - | - | - | - | - | $6,750 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$6,750 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.2176 INCREASE USE OF AUTOMATION |
Savings: $15,206 Cost: $40,000 |
$8,456 | 120,750 | - | - | - | - | - | - | $6,750 | - |
$8,456 120,750 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$6,750 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $74,767 Cost: $130,051 |
$11,920 | 222,743 | $2,960 | 1,163 | $30,549 | - | $15,838 | 5,718 | $13,500 | - | $11,920 222,743 kWh |
$2,960 1,163 kW-months/year |
$30,549 - $ |
$15,838 5,718 MMBtu |
$13,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $34,934 Cost: $47,838 |
$3,464 | 101,993 | $921 | 336 | $30,549 | - | - | - | - | - | $3,464 101,993 kWh |
$921 336 kW-months/year |
$30,549 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes |