IAC logo
IAC Assessment: GT0161
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: GT0161
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Georgia Institute of Technology
Assessment Year 1983
Principal Product DAIRY PRODUCTS
NAICS n/a
SIC 2026 - Fluid Milk
Sales $10,000,000-$50,000,000
# of Employees 242
Plant Area (Sq.Ft.) 0
Annual Production 15,000 Thousand Gallons
Production Hrs. Annual 4,000
Location (State) GA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $292,095 6,544,256 kWh $0.04
Natural Gas $124,586 31,439 MMBtu $3.96
TOTAL ENERGY COSTS $416,681
RECOMMENDED SAVINGS* $40,280 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.2694 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE Savings:
$10,509
Cost:
-
$10,509 448,417 - - $10,509
448,417
kWh
-
-
MMBtu
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$7,694
Cost:
$100
- - $7,694 2,000 -
-
kWh
$7,694
2,000
MMBtu
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$12,395
Cost:
$27,500
- - $12,395 2,718 -
-
kWh
$12,395
2,718
MMBtu
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,407
Cost:
$17,255
$3,407 76,495 - - $3,407
76,495
kWh
-
-
MMBtu
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$6,275
Cost:
$29,686
$6,275 140,973 - - $6,275
140,973
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$40,280
Cost:
$74,541
$20,191 665,885 $20,089 4,718 $20,191
665,885
kWh
$20,089
4,718
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas