Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Georgia Institute of Technology
Assessment Year 1985
Principal Product COLUMNS & SQUAT TURN POST
NAICS n/a
SIC 2431 - Millwork
Sales $1,000,000-$5,000,000
# of Employees 50
Plant Area (Sq.Ft.) 0
Annual Production 40,000 Pieces
Production Hrs. Annual 2,080
Location (State) GA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $18,088 186,987 kWh $0.10
Natural Gas $3,150 542 MMBtu $5.81
TOTAL ENERGY COSTS $21,238
RECOMMENDED SAVINGS* $1,206 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $860
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$860
Cost:
$400
$860 8,792 $860
8,792
kWh
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$122
Cost:
$16
$122 1,172 $122
1,172
kWh
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$224
Cost:
$275
$224 2,345 $224
2,345
kWh
TOTAL RECOMMENDED Savings:
$1,206
Cost:
$691
$1,206 12,309 $1,206
12,309
kWh
TOTAL IMPLEMENTED Savings:
$860
Cost:
$400
$860 8,792 $860
8,792
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage