Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Georgia Institute of Technology
Assessment Year 1986
Principal Product HOME FURNISHINGS
NAICS n/a
SIC 2392 - Housefurnishings, Nec
Sales $10,000,000-$50,000,000
# of Employees 490
Plant Area (Sq.Ft.) 0
Annual Production 37,500 Thousand Feet
Production Hrs. Annual 6,600
Location (State) GA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $168,484 2,944,021 kWh $0.06
Natural Gas $113,343 17,221 MMBtu $6.58
TOTAL ENERGY COSTS $281,827
RECOMMENDED SAVINGS* $51,794 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $23,342
#|Description Savings
Cost
Status Electricity Usage Natural Gas LPG Electricity Usage Natural Gas LPG
$ kWh $ MMBtu $ MMBtu
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$771
Cost:
$919
$771 15,533 - - - - $771
15,533
kWh
-
-
MMBtu
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,192
Cost:
$6,512
$5,192 103,751 - - - - $5,192
103,751
kWh
-
-
MMBtu
-
-
MMBtu
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,049
Cost:
$2,100
$1,049 20,809 - - - - $1,049
20,809
kWh
-
-
MMBtu
-
-
MMBtu
04: 2.7291 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS Savings:
$9,350
Cost:
-
- - $46,685 9,337 $(-37,335) (-9,337) -
-
kWh
$46,685
9,337
MMBtu
$(-37,335)
(-9,337)
MMBtu
05: 2.6122 ADJUST VENTS TO MINIMIZE ENERGY USE Savings:
$3,652
Cost:
$1,000
- - - - $3,652 913 -
-
kWh
-
-
MMBtu
$3,652
913
MMBtu
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$2,580
Cost:
-
$2,580 51,583 - - - - $2,580
51,583
kWh
-
-
MMBtu
-
-
MMBtu
07: 2.7251 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF Savings:
$24,800
Cost:
$49,200
$24,800 183,177 - - - - $24,800
183,177
kWh
-
-
MMBtu
-
-
MMBtu
08: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION Savings:
$4,400
Cost:
$1,000
$4,400 147,714 - - - - $4,400
147,714
kWh
-
-
MMBtu
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$51,794
Cost:
$60,731
$38,792 522,567 $46,685 9,337 $(-33,683) (-8,424) $38,792
522,567
kWh
$46,685
9,337
MMBtu
$(-33,683)
(-8,424)
MMBtu
TOTAL IMPLEMENTED Savings:
$23,342
Cost:
$10,531
$13,992 339,390 $46,685 9,337 $(-37,335) (-9,337) $13,992
339,390
kWh
$46,685
9,337
MMBtu
$(-37,335)
(-9,337)
MMBtu
Savings
Cost
$ kWh $ MMBtu $ MMBtu
Electricity Usage Natural Gas LPG Electricity Usage Natural Gas LPG