Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Georgia Institute of Technology
Assessment Year 1987
Principal Product MOLDED AUTOMOTIVE TRIM
NAICS n/a
SIC 3714 - Motor Vehicle Parts And Accessories
Sales $10,000,000-$50,000,000
# of Employees 100
Plant Area (Sq.Ft.) 0
Annual Production 1,400,000 Pieces
Production Hrs. Annual 4,000
Location (State) GA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $480,432 9,949,883 kWh $0.05
Natural Gas $448,619 94,166 MMBtu $4.76
TOTAL ENERGY COSTS $929,051
RECOMMENDED SAVINGS* $65,765 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $65,765
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE Savings:
$2,070
Cost:
$500
$2,070 42,790 - - $2,070
42,790
kWh
-
-
MMBtu
02: 2.2444 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS Savings:
$15,500
Cost:
$3,500
- - $15,500 3,350 -
-
kWh
$15,500
3,350
MMBtu
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$21,100
Cost:
$6,000
- - $21,100 4,580 -
-
kWh
$21,100
4,580
MMBtu
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$20,500
Cost:
$95,000
- - $20,500 4,440 -
-
kWh
$20,500
4,440
MMBtu
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$5,010
Cost:
$8,940
$5,010 103,751 - - $5,010
103,751
kWh
-
-
MMBtu
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$300
Cost:
$150
$300 6,155 - - $300
6,155
kWh
-
-
MMBtu
07: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,285
Cost:
$2,056
$1,285 26,377 - - $1,285
26,377
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$65,765
Cost:
$116,146
$8,665 179,073 $57,100 12,370 $8,665
179,073
kWh
$57,100
12,370
MMBtu
TOTAL IMPLEMENTED Savings:
$65,765
Cost:
$116,146
$8,665 179,073 $57,100 12,370 $8,665
179,073
kWh
$57,100
12,370
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas