IAC logo
IAC Assessment: GT0345
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: GT0345
IAC Center Georgia Institute of Technology
Assessment Year 1988
Principal Product MEN'S COATS
NAICS n/a
SIC 2311 - Men's and Boys' Suits, Coats, and Overcoats
Sales $10,000,000-$50,000,000
# of Employees 240
Plant Area (Sq.Ft.) 0
Annual Production 1,020,000 Pieces
Production Hrs. Annual 6,000
Location (State) GA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $162,265 2,135,111 kWh $0.08
Natural Gas $21,971 3,899 MMBtu $5.64
TOTAL ENERGY COSTS $184,236
RECOMMENDED SAVINGS* $26,070 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $14,220
#|Description Savings
Cost
Status Electricity Usage Natural Gas Fuel Oil #2 Electricity Usage Natural Gas Fuel Oil #2
$ kWh $ MMBtu $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$12,120
Cost:
$28,140
$12,120 159,437 - - - - $12,120
159,437
kWh
-
-
MMBtu
-
-
MMBtu
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$400
Cost:
$180
$400 5,275 - - - - $400
5,275
kWh
-
-
MMBtu
-
-
MMBtu
03: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$640
Cost:
$425
- - $640 113 - - -
-
kWh
$640
113
MMBtu
-
-
MMBtu
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,060
Cost:
$40
$1,060 14,068 - - - - $1,060
14,068
kWh
-
-
MMBtu
-
-
MMBtu
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$4,366
Cost:
-
$4,366 57,444 - - - - $4,366
57,444
kWh
-
-
MMBtu
-
-
MMBtu
06: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE Savings:
$3,450
Cost:
$2,750
$3,450 76,495 - - - - $3,450
76,495
kWh
-
-
MMBtu
-
-
MMBtu
07: 2.7291 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS Savings:
$4,034
Cost:
$1,000
- - $10,990 1,949 $(-6,956) (-1,949) -
-
kWh
$10,990
1,949
MMBtu
$(-6,956)
(-1,949)
MMBtu
TOTAL RECOMMENDED Savings:
$26,070
Cost:
$32,535
$21,396 312,719 $11,630 2,062 $(-6,956) (-1,949) $21,396
312,719
kWh
$11,630
2,062
MMBtu
$(-6,956)
(-1,949)
MMBtu
TOTAL IMPLEMENTED Savings:
$14,220
Cost:
$28,785
$13,580 178,780 $640 113 - - $13,580
178,780
kWh
$640
113
MMBtu
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu $ MMBtu
Electricity Usage Natural Gas Fuel Oil #2 Electricity Usage Natural Gas Fuel Oil #2