Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Georgia Institute of Technology
Assessment Year 1993
Principal Product Polyester / Cotton Cloth
NAICS n/a
SIC 2211 - Broadwoven Fabric Mills, Cotton
Sales $10,000,000-$50,000,000
# of Employees 411
Plant Area (Sq.Ft.) 0
Annual Production 2,800,000 Thousand Feet
Production Hrs. Annual 8,600
Location (State) SC
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,257,674 31,002,345 kWh $0.04
Natural Gas $87,750 33,853 MMBtu $2.59
TOTAL ENERGY COSTS $1,345,424
RECOMMENDED SAVINGS* $89,485 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $56,310
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$1,080
Cost:
-
- - $1,080 418 -
-
kWh
$1,080
418
MMBtu
02: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$4,060
Cost:
$9,600
- - $4,060 1,566 -
-
kWh
$4,060
1,566
MMBtu
03: 2.1242 MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT Savings:
$840
Cost:
-
- - $840 324 -
-
kWh
$840
324
MMBtu
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$34,740
Cost:
$27,740
$34,740 855,803 - - $34,740
855,803
kWh
-
-
MMBtu
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$15,270
Cost:
-
$15,270 376,319 - - $15,270
376,319
kWh
-
-
MMBtu
06: 2.2531 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR Savings:
$620
Cost:
-
$620 15,240 - - $620
15,240
kWh
-
-
MMBtu
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,950
Cost:
-
$1,950 48,066 - - $1,950
48,066
kWh
-
-
MMBtu
08: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$2,650
Cost:
$1,010
$2,650 65,064 - - $2,650
65,064
kWh
-
-
MMBtu
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$28,275
Cost:
$87,090
$28,275 696,659 - - $28,275
696,659
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$89,485
Cost:
$125,440
$83,505 2,057,151 $5,980 2,308 $83,505
2,057,151
kWh
$5,980
2,308
MMBtu
TOTAL IMPLEMENTED Savings:
$56,310
Cost:
$28,750
$55,230 1,360,492 $1,080 418 $55,230
1,360,492
kWh
$1,080
418
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas