Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 1996 |
Principal Product | Apparel |
NAICS | n/a |
SIC | 2322 - Men's and Boys' Underwear and Nightwear |
Sales | $10,000,000-$50,000,000 |
# of Employees | 280 |
Plant Area (Sq.Ft.) | 163,200 |
Annual Production | 1,300,000 Pieces |
Production Hrs. Annual | 2,000 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $112,864 | 2,531,946 | kWh | $0.04 |
Electricity Demand | $87,789 | 11,352 | kW-months/year | $7.73 |
Electricity Fees | $10,033 | - | $ | - |
Natural Gas | $2,024 | 256 | MMBtu | $7.91 |
TOTAL ENERGY COSTS | $218,050 | |||
RECOMMENDED SAVINGS* | $33,830 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $33,630 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8112 COMBINE UTILITY METERS |
Savings: $9,200 Cost: $18,400 |
- | - | - | - | $9,200 | - | - | - |
- - kWh |
- - kW-months/year |
$9,200 - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7229 AIR CONDITION ONLY SPACE NECESSARY |
Savings: $17,420 Cost: $15,000 |
$12,515 | 345,545 | $4,075 | 527 | $830 | - | - | - |
$12,515 345,545 kWh |
$4,075 527 kW-months/year |
$830 - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $90 Cost: $3,900 |
$44 | 879 | $42 | 5 | $4 | - | - | - |
$44 879 kWh |
$42 5 kW-months/year |
$4 - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $200 Cost: $360 |
$144 | 2,052 | $46 | 6 | $10 | - | - | - |
$144 2,052 kWh |
$46 6 kW-months/year |
$10 - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $390 Cost: $500 |
$201 | 3,810 | $170 | 22 | $19 | - | - | - |
$201 3,810 kWh |
$170 22 kW-months/year |
$19 - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $390 Cost: - |
$270 | 7,034 | $101 | 13 | $19 | - | - | - |
$270 7,034 kWh |
$101 13 kW-months/year |
$19 - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,860 Cost: $3,000 |
$666 | 12,016 | $534 | 69 | $60 | - | $600 | 90 |
$666 12,016 kWh |
$534 69 kW-months/year |
$60 - $ |
$600 90 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5217 REUSE / RECYCLE/ SELL PAPER PRODUCTS |
Savings: $4,280 Cost: $7,050 |
- | - | - | - | - | - | $4,280 | 230,000 |
- - kWh |
- - kW-months/year |
- - $ |
$4,280 230,000 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $33,830 Cost: $48,210 |
$13,840 | 371,336 | $4,968 | 642 | $10,142 | - | $4,880 | 230,090 | $13,840 371,336 kWh |
$4,968 642 kW-months/year |
$10,142 - $ |
$4,880 230,090 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $33,630 Cost: $47,850 |
$13,696 | 369,284 | $4,922 | 636 | $10,132 | - | $4,880 | 230,090 | $13,696 369,284 kWh |
$4,922 636 kW-months/year |
$10,132 - $ |
$4,880 230,090 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) |