Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 1998 |
Principal Product | Computer Monitors |
NAICS | n/a |
SIC | 3575 - Computer Terminals |
Sales | >$500,000,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 290,000 |
Annual Production | 1,300,000 Pieces |
Production Hrs. Annual | 6,000 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $98,392 | 3,920,868 | kWh | $0.03 |
Electricity Demand | $147,916 | 13,374 | kW-months/year | $11.06 |
Electricity Fees | $71,087 | - | $ | - |
Natural Gas | $41,348 | 7,052 | MMBtu | $5.86 |
TOTAL ENERGY COSTS | $1,684,278 | |||
RECOMMENDED SAVINGS* | $161,896 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,980 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $8,713 Cost: $22,000 |
$3,648 | 144,783 | $5,065 | 458 | - | - | - | - | - | - | - | - |
$3,648 144,783 kWh |
$5,065 458 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.4155 METER WASTE WATER |
Savings: $1,215 Cost: $1,500 |
- | - | - | - | - | - | $1,215 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,215 - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $108,000 Cost: - |
- | - | - | - | - | - | - | - | $108,000 | 3,600,000 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$108,000 3,600,000 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $2,020 Cost: $2,700 |
- | - | $2,020 | 183 | - | - | - | - | - | - | - | - |
- - kWh |
$2,020 183 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $2,730 Cost: $10,050 |
$2,730 | 108,441 | - | - | - | - | - | - | - | - | - | - |
$2,730 108,441 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $1,230 Cost: $400 |
$1,230 | 48,652 | - | - | - | - | - | - | - | - | - | - |
$1,230 48,652 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.454 MODIFY STARTUP/SHUTDOWN TIMES |
Savings: $37,988 Cost: - |
$3,288 | 130,422 | - | - | $3,500 | 597 | - | - | - | - | $31,200 | - |
$3,288 130,422 kWh |
- - kW-months/year |
$3,500 597 MMBtu |
- - Tgal |
- - lb |
$31,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $161,896 Cost: $36,650 |
$10,896 | 432,298 | $7,085 | 641 | $3,500 | 597 | $1,215 | - | $108,000 | 3,600,000 | $31,200 | - | $10,896 432,298 kWh |
$7,085 641 kW-months/year |
$3,500 597 MMBtu |
$1,215 - Tgal |
$108,000 3,600,000 lb |
$31,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,980 Cost: $13,150 |
$3,960 | 157,093 | $2,020 | 183 | - | - | - | - | - | - | - | - | $3,960 157,093 kWh |
$2,020 183 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Personnel Changes |