Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 2001 |
Principal Product | Print Fabrics |
NAICS | n/a |
SIC | 2269 - Finishing Plants, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 90 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 9,000 Thousand Feet |
Production Hrs. Annual | 6,000 |
Location (State) | SC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $154,487 | 3,029,160 | kWh | $0.05 |
Electricity Demand | $79,762 | 13,033 | kW-months/year | $6.12 |
Electricity Fees | $19,175 | - | $ | - |
Natural Gas | $480,739 | 99,272 | MMBtu | $4.84 |
TOTAL ENERGY COSTS | $924,654 | |||
RECOMMENDED SAVINGS* | $208,329 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $64,562 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Water Consumption | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1211 MOVE BOILER TO MORE EFFICIENT LOCATION |
Savings: $7,140 Cost: - |
- | - | - | - | - | - | $7,140 | 1,608 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$7,140 1,608 MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $4,765 Cost: - |
- | - | - | - | - | - | $6,265 | 1,411 | $(-1,500) | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$6,265 1,411 MMBtu |
$(-1,500) - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.8112 COMBINE UTILITY METERS |
Savings: $11,677 Cost: $1,000 |
- | - | - | - | $11,677 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$11,677 - $ |
- - MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1113 REDUCE COMBUSTION AIR FLOW TO OPTIMUM |
Savings: $38,843 Cost: $13,500 |
- | - | - | - | - | - | $38,843 | 4,522 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$38,843 4,522 MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER |
Savings: $132,090 Cost: $60,000 |
- | - | - | - | - | - | $132,090 | 29,750 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$132,090 29,750 MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $9,164 Cost: $10,500 |
- | - | - | - | - | - | $8,905 | 1,505 | - | - | $259 | - |
- - kWh |
- - kW-months/year |
- - $ |
$8,905 1,505 MMBtu |
- - $ |
$259 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,650 Cost: $21,400 |
$3,528 | 69,168 | $813 | 133 | $309 | - | - | - | - | - | - | - |
$3,528 69,168 kWh |
$813 133 kW-months/year |
$309 - $ |
- - MMBtu |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $208,329 Cost: $106,400 |
$3,528 | 69,168 | $813 | 133 | $11,986 | - | $193,243 | 38,796 | $(-1,500) | - | $259 | - | $3,528 69,168 kWh |
$813 133 kW-months/year |
$11,986 - $ |
$193,243 38,796 MMBtu |
$(-1,500) - $ |
$259 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $64,562 Cost: $45,400 |
$3,528 | 69,168 | $813 | 133 | $309 | - | $61,153 | 9,046 | $(-1,500) | - | $259 | - | $3,528 69,168 kWh |
$813 133 kW-months/year |
$309 - $ |
$61,153 9,046 MMBtu |
$(-1,500) - $ |
$259 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Water Consumption | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Water Consumption |