IAC logo
IAC Assessment: GT0711
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: GT0711
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Georgia Institute of Technology
Assessment Year 2001
Principal Product Circuit Boards
NAICS n/a
SIC 3672 - Printed Circuit Boards
Sales $10,000,000-$50,000,000
# of Employees 75
Plant Area (Sq.Ft.) 50,000
Annual Production 250,000 Pieces
Production Hrs. Annual 5,000
Location (State) GA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $18,749 604,800 kWh $0.03
Electricity Demand $19,634 1,823 kW-months/year $10.77
Electricity Fees $7,557 - $ -
Natural Gas $3,061 319 MMBtu $9.60
TOTAL ENERGY COSTS $49,001
RECOMMENDED SAVINGS* $10,436 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $860
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Natural Gas Administrative Changes Ancillary Material Cost Electricity Usage Electricity Demand Electricity Fees Natural Gas Administrative Changes Ancillary Material Cost
$ kWh $ kW-months/year $ $ $ MMBtu $ $ $ $
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE Savings:
$6,495
Cost:
$2,000
- - - - $6,495 - - - - - - - -
-
kWh
-
-
kW-months/year
$6,495
-
$
-
-
MMBtu
-
-
$
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,025
Cost:
$3,725
$981 31,654 $910 85 $134 - - - - - - - $981
31,654
kWh
$910
85
kW-months/year
$134
-
$
-
-
MMBtu
-
-
$
-
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$845
Cost:
$1,450
$277 8,936 $514 48 $54 - - - - - - - $277
8,936
kWh
$514
48
kW-months/year
$54
-
$
-
-
MMBtu
-
-
$
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$331
Cost:
$310
$64 2,078 $30 3 - - - - $27 - $210 - $64
2,078
kWh
$30
3
kW-months/year
-
-
$
-
-
MMBtu
$27
-
$
$210
-
$
05: 2.6241 REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY Savings:
$15
Cost:
-
$15 495 - - - - - - - - - - $15
495
kWh
-
-
kW-months/year
-
-
$
-
-
MMBtu
-
-
$
-
-
$
06: 2.4314 USE SYNTHETIC LUBRICANT Savings:
$75
Cost:
-
$24 778 $46 4 $5 - - - - - - - $24
778
kWh
$46
4
kW-months/year
$5
-
$
-
-
MMBtu
-
-
$
-
-
$
07: 2.2222 CONVERT LIQUID HEATERS FROM UNDERFIRING TO IMMERSION OR SUBMERSION HEATING Savings:
$140
Cost:
$800
$140 4,463 - - - - - - - - - - $140
4,463
kWh
-
-
kW-months/year
-
-
$
-
-
MMBtu
-
-
$
-
-
$
08: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$510
Cost:
$225
$60 1,940 - - - - $450 47 - - - - $60
1,940
kWh
-
-
kW-months/year
-
-
$
$450
47
MMBtu
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$10,436
Cost:
$8,510
$1,561 50,344 $1,500 140 $6,688 - $450 47 $27 - $210 - $1,561
50,344
kWh
$1,500
140
kW-months/year
$6,688
-
$
$450
47
MMBtu
$27
-
$
$210
-
$
TOTAL IMPLEMENTED Savings:
$860
Cost:
$1,450
$292 9,431 $514 48 $54 - - - - - - - $292
9,431
kWh
$514
48
kW-months/year
$54
-
$
-
-
MMBtu
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ MMBtu $ $ $ $
Electricity Usage Electricity Demand Electricity Fees Natural Gas Administrative Changes Ancillary Material Cost Electricity Usage Electricity Demand Electricity Fees Natural Gas Administrative Changes Ancillary Material Cost