Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 2001 |
Principal Product | Tire Retread |
NAICS | n/a |
SIC | 3069 - Fabricated Rubber Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 126,000 |
Annual Production | 700,000 Pieces |
Production Hrs. Annual | 8,400 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $453,167 | 18,602,914 | kWh | $0.02 |
Electricity Demand | $403,241 | 35,372 | kW-months/year | $11.40 |
Electricity Fees | $83,547 | - | $ | - |
Natural Gas | $637,755 | 74,993 | MMBtu | $8.50 |
TOTAL ENERGY COSTS | $1,577,710 | |||
RECOMMENDED SAVINGS* | $239,162 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $14,000 Cost: - |
- | - | - | - | $20,000 | - | $(-6,000) | - | - | - |
- - kWh |
- - kW-months/year |
$20,000 - $ |
$(-6,000) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8112 COMBINE UTILITY METERS |
Savings: $2,360 Cost: - |
- | - | - | - | - | - | - | - | $2,360 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
$2,360 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4235 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES |
Savings: $645 Cost: - |
$610 | 25,032 | - | - | $35 | - | - | - | - | - |
$610 25,032 kWh |
- - kW-months/year |
$35 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $1,625 Cost: $7,000 |
$1,536 | 63,040 | - | - | $89 | - | - | - | - | - |
$1,536 63,040 kWh |
- - kW-months/year |
$89 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1114 LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE |
Savings: $35,705 Cost: $3,500 |
- | - | - | - | $35,705 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$35,705 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.445 INSTALL EQUIPMENT TO MOVE PRODUCT |
Savings: $99,000 Cost: $80,000 |
- | - | - | - | - | - | $99,000 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$99,000 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2426 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR |
Savings: $12,400 Cost: $30,000 |
- | - | - | - | $12,400 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$12,400 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.8131 USE WATER-BASED ADHESIVES |
Savings: $73,300 Cost: $20,000 |
$1,604 | 65,856 | $1,532 | 134 | $70,164 | - | - | - | - | - |
$1,604 65,856 kWh |
$1,532 134 kW-months/year |
$70,164 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.8112 COMBINE UTILITY METERS |
Savings: $127 Cost: - |
- | - | - | - | - | - | - | - | $127 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
$127 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $239,162 Cost: $140,500 |
$3,750 | 153,928 | $1,532 | 134 | $138,393 | - | $93,000 | - | $2,487 | - | $3,750 153,928 kWh |
$1,532 134 kW-months/year |
$138,393 - $ |
$93,000 - $ |
$2,487 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes |