Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 2001 |
Principal Product | Textile Chemicals |
NAICS | n/a |
SIC | 2843 - Surface Active Agents |
Sales | $10,000,000-$50,000,000 |
# of Employees | 30 |
Plant Area (Sq.Ft.) | 41,050 |
Annual Production | 22,000 Thousand Gallons |
Production Hrs. Annual | 4,500 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $13,338 | 535,680 | kWh | $0.02 |
Electricity Demand | $6,077 | 1,674 | kW-months/year | $3.63 |
Electricity Fees | $3,551 | - | $ | - |
Natural Gas | $89,241 | 13,258 | MMBtu | $6.73 |
TOTAL ENERGY COSTS | $134,102 | |||
RECOMMENDED SAVINGS* | $27,349 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $17,459 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Ancillary Material Cost | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT |
Savings: $16,455 Cost: $5,110 |
$(-319) | (-12,800) | $(-664) | (-183) | $(-60) | - | $17,498 | 2,600 | - | - | - | - | - | - |
$(-319) (-12,800) kWh |
$(-664) (-183) kW-months/year |
$(-60) - $ |
$17,498 2,600 MMBtu |
- - Tgal |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $851 Cost: $2,902 |
$430 | 17,288 | $374 | 103 | $47 | - | - | - | - | - | - | - | - | - |
$430 17,288 kWh |
$374 103 kW-months/year |
$47 - $ |
- - MMBtu |
- - Tgal |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $351 Cost: $727 |
$122 | 4,906 | $22 | 6 | $10 | - | - | - | - | - | $197 | - | - | - |
$122 4,906 kWh |
$22 6 kW-months/year |
$10 - $ |
- - MMBtu |
- - Tgal |
$197 - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER |
Savings: $6,753 Cost: $18,500 |
$(-1,670) | (-67,050) | - | - | - | - | - | - | $6,659 | 6,465,000 | $(-1,300) | - | $3,064 | - |
$(-1,670) (-67,050) kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$6,659 6,465,000 Tgal |
$(-1,300) - $ |
$3,064 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2123 INSULATE FEEDWATER TANK |
Savings: $153 Cost: $220 |
- | - | - | - | - | - | $153 | 23 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$153 23 MMBtu |
- - Tgal |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $2,786 Cost: $4,000 |
- | - | - | - | - | - | $2,786 | 414 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$2,786 414 MMBtu |
- - Tgal |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $27,349 Cost: $31,459 |
$(-1,437) | (-57,656) | $(-268) | (-74) | $(-3) | - | $20,437 | 3,037 | $6,659 | 6,465,000 | $(-1,103) | - | $3,064 | - | $(-1,437) (-57,656) kWh |
$(-268) (-74) kW-months/year |
$(-3) - $ |
$20,437 3,037 MMBtu |
$6,659 6,465,000 Tgal |
$(-1,103) - $ |
$3,064 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $17,459 Cost: $8,232 |
$111 | 4,488 | $(-290) | (-80) | $(-13) | - | $17,651 | 2,623 | - | - | - | - | - | - | $111 4,488 kWh |
$(-290) (-80) kW-months/year |
$(-13) - $ |
$17,651 2,623 MMBtu |
- - Tgal |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Ancillary Material Cost | Water Consumption |