Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Georgia Institute of Technology
Assessment Year 2003
Principal Product PET CONTAINERS
NAICS 326160 - Plastics Bottle Manufacturing
SIC 3085 - Plastics Bottles
Sales n/a
# of Employees 220
Plant Area (Sq.Ft.) 315,000
Annual Production 900,000,000 Pieces
Production Hrs. Annual 8,760
Location (State) NC
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,704,406 68,637,600 kWh $0.02
Electricity Demand $1,631,878 24,180 kW-months/year $67.49
Electricity Fees $290,112 - $ -
Natural Gas $398,568 76,551 MMBtu $5.21
TOTAL ENERGY COSTS $4,024,964
RECOMMENDED SAVINGS* $1,108,710 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE Savings:
$116,954
Cost:
$2,000
- - - - - - $116,954 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$116,954
-
$
02: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE Savings:
$44,604
Cost:
$85,000
- - - - - - $44,604 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$44,604
-
$
03: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$28,809
Cost:
-
- - $28,809 2,820 - - - - -
-
kWh
$28,809
2,820
kW-months/year
-
-
MMBtu
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,314
Cost:
$2,844
$2,534 96,710 $1,780 132 - - - - $2,534
96,710
kWh
$1,780
132
kW-months/year
-
-
MMBtu
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,272
Cost:
$17,760
$1,176 44,913 $3,096 228 - - - - $1,176
44,913
kWh
$3,096
228
kW-months/year
-
-
MMBtu
-
-
$
06: 2.2211 USE OPTIMUM TEMPERATURE Savings:
$76,382
Cost:
$16,640
$32,474 1,205,000 $43,908 3,048 - - - - $32,474
1,205,000
kWh
$43,908
3,048
kW-months/year
-
-
MMBtu
-
-
$
07: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD Savings:
$22,400
Cost:
$22,800
$12,851 477,000 $9,549 660 - - - - $12,851
477,000
kWh
$9,549
660
kW-months/year
-
-
MMBtu
-
-
$
08: 2.3417 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT Savings:
$810,975
Cost:
$4,250,000
$565,979 18,093,440 $1,002,100 71,232 $(-757,104) (-145,597) - - $565,979
18,093,440
kWh
$1,002,100
71,232
kW-months/year
$(-757,104)
(-145,597)
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$1,108,710
Cost:
$4,397,044
$615,014 19,917,063 $1,089,242 78,120 $(-757,104) (-145,597) $161,558 - $615,014
19,917,063
kWh
$1,089,242
78,120
kW-months/year
$(-757,104)
(-145,597)
MMBtu
$161,558
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes