Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 2003 |
Principal Product | PET CONTAINERS |
NAICS | 326160 - Plastics Bottle Manufacturing |
SIC | 3085 - Plastics Bottles |
Sales | n/a |
# of Employees | 220 |
Plant Area (Sq.Ft.) | 315,000 |
Annual Production | 900,000,000 Pieces |
Production Hrs. Annual | 8,760 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,704,406 | 68,637,600 | kWh | $0.02 |
Electricity Demand | $1,631,878 | 24,180 | kW-months/year | $67.49 |
Electricity Fees | $290,112 | - | $ | - |
Natural Gas | $398,568 | 76,551 | MMBtu | $5.21 |
TOTAL ENERGY COSTS | $4,024,964 | |||
RECOMMENDED SAVINGS* | $1,108,710 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $116,954 Cost: $2,000 |
- | - | - | - | - | - | $116,954 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$116,954 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $44,604 Cost: $85,000 |
- | - | - | - | - | - | $44,604 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$44,604 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $28,809 Cost: - |
- | - | $28,809 | 2,820 | - | - | - | - |
- - kWh |
$28,809 2,820 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,314 Cost: $2,844 |
$2,534 | 96,710 | $1,780 | 132 | - | - | - | - |
$2,534 96,710 kWh |
$1,780 132 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,272 Cost: $17,760 |
$1,176 | 44,913 | $3,096 | 228 | - | - | - | - |
$1,176 44,913 kWh |
$3,096 228 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2211 USE OPTIMUM TEMPERATURE |
Savings: $76,382 Cost: $16,640 |
$32,474 | 1,205,000 | $43,908 | 3,048 | - | - | - | - |
$32,474 1,205,000 kWh |
$43,908 3,048 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $22,400 Cost: $22,800 |
$12,851 | 477,000 | $9,549 | 660 | - | - | - | - |
$12,851 477,000 kWh |
$9,549 660 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.3417 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT |
Savings: $810,975 Cost: $4,250,000 |
$565,979 | 18,093,440 | $1,002,100 | 71,232 | $(-757,104) | (-145,597) | - | - |
$565,979 18,093,440 kWh |
$1,002,100 71,232 kW-months/year |
$(-757,104) (-145,597) MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,108,710 Cost: $4,397,044 |
$615,014 | 19,917,063 | $1,089,242 | 78,120 | $(-757,104) | (-145,597) | $161,558 | - | $615,014 19,917,063 kWh |
$1,089,242 78,120 kW-months/year |
$(-757,104) (-145,597) MMBtu |
$161,558 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes |