Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 2003 |
Principal Product | BAKERY GOODS |
NAICS | 311821 - Cookie and Cracker Manufacturing |
SIC | 2051 - Bread, Cake, And Related Products |
Sales | $50,000,000-$100,000,000 |
# of Employees | 382 |
Plant Area (Sq.Ft.) | 51,363,918 |
Annual Production | 41,999,871 Pounds |
Production Hrs. Annual | 2,500 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $619,064 | 11,664,798 | kWh | $0.05 |
Natural Gas | $202,200 | 60,370 | MMBtu | $3.35 |
TOTAL ENERGY COSTS | $821,264 | |||
RECOMMENDED SAVINGS* | $361,675 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $233 Cost: - |
$233 | 18,304 | - | - | - | - | - | - | - | - |
$233 18,304 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $27,457 Cost: - |
$27,457 | 893,200 | - | - | - | - | - | - | - | - |
$27,457 893,200 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.8118 CHECK FOR ACCURACY OF UTILITY / POWER METERS |
Savings: $21,000 Cost: $8,220 |
- | - | - | - | - | - | - | - | $21,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$21,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $64,596 Cost: $238,800 |
$35,412 | 1,018,368 | $29,184 | 408 | - | - | - | - | - | - |
$35,412 1,018,368 kWh |
$29,184 408 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $3,035 Cost: - |
$3,035 | 87,279 | - | - | - | - | - | - | - | - |
$3,035 87,279 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1113 REDUCE COMBUSTION AIR FLOW TO OPTIMUM |
Savings: $3,160 Cost: - |
- | - | - | - | $5,660 | 1,691 | $(-2,500) | - | - | - |
- - kWh |
- - kW-months/year |
$5,660 1,691 MMBtu |
$(-2,500) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $200,750 Cost: $814,000 |
$253,700 | 3,000,000 | - | - | $(-52,950) | (-11,325) | - | - | - | - |
$253,700 3,000,000 kWh |
- - kW-months/year |
$(-52,950) (-11,325) MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $41,444 Cost: $500 |
$30,715 | 762,551 | $10,729 | 75 | - | - | - | - | - | - |
$30,715 762,551 kWh |
$10,729 75 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $361,675 Cost: $1,061,520 |
$350,552 | 5,779,702 | $39,913 | 483 | $(-47,290) | (-9,634) | $(-2,500) | - | $21,000 | - | $350,552 5,779,702 kWh |
$39,913 483 kW-months/year |
$(-47,290) (-9,634) MMBtu |
$(-2,500) - $ |
$21,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost |