Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 2004 |
Principal Product | PLASTIC CRATES |
NAICS | 326199 - All Other Plastics Product Manufacturing |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 120 |
Plant Area (Sq.Ft.) | 90,000 |
Annual Production | 50,000,000 Pounds |
Production Hrs. Annual | 8,400 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $672,907 | 25,108,808 | kWh | $0.03 |
Electricity Demand | $421,448 | 34,944 | kW-months/year | $12.06 |
Electricity Fees | $65,829 | - | $ | - |
Natural Gas | $9,007 | 666 | MMBtu | $13.52 |
TOTAL ENERGY COSTS | $1,169,191 | |||
RECOMMENDED SAVINGS* | $266,660 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $149,190 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.7311 MAINTAIN MACHINES TO REDUCE LEAKS |
Savings: $121,900 Cost: $45,000 |
- | - | - | - | $121,900 | 48,000 | - | - |
- - kWh |
- - kW-months/year |
$121,900 48,000 gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $33,950 Cost: $38,000 |
$33,950 | 918,750 | - | - | - | - | - | - |
$33,950 918,750 kWh |
- - kW-months/year |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2625 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE |
Savings: $33,280 Cost: $25,000 |
$21,850 | 591,360 | $11,430 | 845 | - | - | - | - |
$21,850 591,360 kWh |
$11,430 845 kW-months/year |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $27,700 Cost: $22,500 |
$27,700 | 750,000 | - | - | - | - | - | - |
$27,700 750,000 kWh |
- - kW-months/year |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2615 CLEAN CONDENSER TUBES |
Savings: $22,690 Cost: $3,000 |
$14,900 | 403,200 | $7,790 | 576 | - | - | - | - |
$14,900 403,200 kWh |
$7,790 576 kW-months/year |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $19,500 Cost: - |
- | - | $19,500 | 1,440 | - | - | - | - |
- - kWh |
$19,500 1,440 kW-months/year |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $4,600 Cost: $35 |
- | - | - | - | - | - | $4,600 | - |
- - kWh |
- - kW-months/year |
- - gal |
$4,600 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,040 Cost: $3,737 |
$2,000 | 54,096 | $1,040 | 77 | - | - | - | - |
$2,000 54,096 kWh |
$1,040 77 kW-months/year |
- - gal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $266,660 Cost: $137,272 |
$100,400 | 2,717,406 | $39,760 | 2,938 | $121,900 | 48,000 | $4,600 | - | $100,400 2,717,406 kWh |
$39,760 2,938 kW-months/year |
$121,900 48,000 gal |
$4,600 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $149,190 Cost: $48,035 |
$14,900 | 403,200 | $7,790 | 576 | $121,900 | 48,000 | $4,600 | - | $14,900 403,200 kWh |
$7,790 576 kW-months/year |
$121,900 48,000 gal |
$4,600 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Administrative Changes |