Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 2006 |
Principal Product | Vinyl Coated Mesh Fabric |
NAICS | 313320 - Fabric Coating Mills |
SIC | 2295 - Coated Fabrics, Not Rubberized |
Sales | $5,000,000-$10,000,000 |
# of Employees | 70 |
Plant Area (Sq.Ft.) | 50,000 |
Annual Production | 1,170 Thousand Feet |
Production Hrs. Annual | 8,720 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $41,495 | 1,212,960 | kWh | $0.03 |
Electricity Demand | $36,072 | 2,666 | kW-months/year | $13.53 |
Natural Gas | $164,926 | 10,459 | MMBtu | $15.77 |
TOTAL ENERGY COSTS | $242,493 | |||
RECOMMENDED SAVINGS* | $183,603 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $7,076 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,499 Cost: $4,242 |
$4,037 | 118,033 | $2,462 | 162 | - | - | - | - |
$4,037 118,033 kWh |
$2,462 162 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $577 Cost: $356 |
$358 | 10,464 | $219 | 14 | - | - | - | - |
$358 10,464 kWh |
$219 14 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.5113 USE DIRECT FLAME IMPINGEMENT OR INFRARED PROCESSING FOR CHAMBER TYPE HEATING |
Savings: $71,569 Cost: $250,000 |
$(-54,141) | (-1,583,080) | $(-39,216) | (-2,580) | $164,926 | 10,459 | - | - |
$(-54,141) (-1,583,080) kWh |
$(-39,216) (-2,580) kW-months/year |
$164,926 10,459 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $46,640 Cost: $7,200 |
- | - | - | - | - | - | $46,640 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$46,640 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1113 REDUCE COMBUSTION AIR FLOW TO OPTIMUM |
Savings: $37,004 Cost: $3,300 |
- | - | - | - | $37,004 | 2,342 | - | - |
- - kWh |
- - kW-months/year |
$37,004 2,342 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $21,314 Cost: $7,500 |
- | - | - | - | $21,314 | 1,349 | - | - |
- - kWh |
- - kW-months/year |
$21,314 1,349 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $183,603 Cost: $272,598 |
$(-49,746) | (-1,454,583) | $(-36,535) | (-2,404) | $223,244 | 14,150 | $46,640 | - | $(-49,746) (-1,454,583) kWh |
$(-36,535) (-2,404) kW-months/year |
$223,244 14,150 MMBtu |
$46,640 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $7,076 Cost: $4,598 |
$4,395 | 128,497 | $2,681 | 176 | - | - | - | - | $4,395 128,497 kWh |
$2,681 176 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes |