Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 2008 |
Principal Product | Kraft Paper |
NAICS | 322130 - Paperboard Mills |
SIC | 2631 - Paperboard Mills |
Sales | $100,000,000-$500,000,000 |
# of Employees | 273 |
Plant Area (Sq.Ft.) | 3,000,000 |
Annual Production | 315,000 Tons |
Production Hrs. Annual | 8,400 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $4,084,356 | 110,983,405 | kWh | $0.04 |
Natural Gas | $4,490,760 | 6,195,838 | MMBtu | $0.72 |
TOTAL ENERGY COSTS | $8,575,116 | |||
RECOMMENDED SAVINGS* | $887,973 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $292,310 |
#|Description |
Savings Cost |
Status | Electricity Usage | Wood | Other Energy | Water Consumption | Electricity Usage | Wood | Other Energy | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | MMBtu | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1331 BURN A LESS EXPENSIVE GRADE OF FUEL |
Savings: $98,980 Cost: - |
- | - | - | - | $98,980 | - | - | - |
- - kWh |
- - MMBtu |
$98,980 - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.6123 BURN WOOD BY-PRODUCTS FOR HEAT |
Savings: $175,600 Cost: $100,000 |
- | - | $175,600 | 395,405 | - | - | - | - |
- - kWh |
$175,600 395,405 MMBtu |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1241 REDUCE EXCESSIVE BOILER BLOWDOWN |
Savings: $57,260 Cost: - |
$3,256 | 59,200 | - | - | $34,466 | 23,575 | $19,538 | - |
$3,256 59,200 kWh |
- - MMBtu |
$34,466 23,575 MMBtu |
$19,538 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED |
Savings: $292,310 Cost: $18,200 |
$15,220 | 276,700 | - | - | $185,770 | 83,680 | $91,320 | - |
$15,220 276,700 kWh |
- - MMBtu |
$185,770 83,680 MMBtu |
$91,320 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $35,083 Cost: $40,800 |
- | - | - | - | $35,083 | 15,803 | - | - |
- - kWh |
- - MMBtu |
$35,083 15,803 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3412 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR |
Savings: $228,740 Cost: $900,000 |
$1,070,900 | 19,471,200 | - | - | $(-842,160) | (-379,350) | - | - |
$1,070,900 19,471,200 kWh |
- - MMBtu |
$(-842,160) (-379,350) MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $887,973 Cost: $1,059,000 |
$1,089,376 | 19,807,100 | $175,600 | 395,405 | $(-487,861) | (-256,292) | $110,858 | - | $1,089,376 19,807,100 kWh |
$175,600 395,405 MMBtu |
$(-487,861) (-256,292) MMBtu |
$110,858 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $292,310 Cost: $18,200 |
$15,220 | 276,700 | - | - | $185,770 | 83,680 | $91,320 | - | $15,220 276,700 kWh |
- - MMBtu |
$185,770 83,680 MMBtu |
$91,320 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | MMBtu | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Wood | Other Energy | Water Consumption | Electricity Usage | Wood | Other Energy | Water Consumption |