Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 2010 |
Principal Product | Needle Roller Bearings |
NAICS | 332991 - Ball and Roller Bearing Manufacturing |
SIC | 3562 - Ball And Roller Bearings |
Sales | $50,000,000-$100,000,000 |
# of Employees | 325 |
Plant Area (Sq.Ft.) | 267,000 |
Annual Production | 100,000,000 Pieces |
Production Hrs. Annual | 8,760 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $584,872 | 21,661,909 | kWh | $0.03 |
Electricity Demand | $636,225 | 42,415 | kW-months/year | $15.00 |
Electricity Fees | $39,237 | - | $ | - |
Natural Gas | $378,618 | 67,440 | MMBtu | $5.61 |
TOTAL ENERGY COSTS | $1,638,952 | |||
RECOMMENDED SAVINGS* | $511,106 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $35,036 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,133 Cost: $1,250 |
$643 | 23,827 | $490 | 33 | - | - |
$643 23,827 kWh |
$490 33 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $1,632 Cost: - |
$926 | 34,302 | $706 | 47 | - | - |
$926 34,302 kWh |
$706 47 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $53,185 Cost: $6,187 |
$53,185 | 1,969,782 | - | - | - | - |
$53,185 1,969,782 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $6,159 Cost: $2,883 |
$6,159 | 228,125 | - | - | - | - |
$6,159 228,125 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $19,038 Cost: $20,250 |
$19,038 | 705,120 | - | - | - | - |
$19,038 705,120 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $10,115 Cost: $38,366 |
$4,576 | 169,481 | $5,539 | 369 | - | - |
$4,576 169,481 kWh |
$5,539 369 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $27,744 Cost: $119,989 |
$12,552 | 464,875 | $15,192 | 1,013 | - | - |
$12,552 464,875 kWh |
$15,192 1,013 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7273 INSTALL DESICCANT HUMIDITY CONTROL SYSTEM |
Savings: $392,100 Cost: $177,900 |
$71,880 | 2,662,143 | $61,720 | 4,115 | $258,500 | 42,586 |
$71,880 2,662,143 kWh |
$61,720 4,115 kW-months/year |
$258,500 42,586 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $511,106 Cost: $366,825 |
$168,959 | 6,257,655 | $83,647 | 5,577 | $258,500 | 42,586 | $168,959 6,257,655 kWh |
$83,647 5,577 kW-months/year |
$258,500 42,586 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $35,036 Cost: $124,122 |
$19,354 | 716,827 | $15,682 | 1,046 | - | - | $19,354 716,827 kWh |
$15,682 1,046 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |