Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Georgia Institute of Technology
Assessment Year 2025
Principal Product Printed Circuit Assemblies
NAICS 334418 - Printed Circuit Assembly (Electronic Assembly) Manufacturing
SIC 3672 - Printed Circuit Boards
Sales $50,000,000-$100,000,000
# of Employees 208
Plant Area (Sq.Ft.) 70,000
Annual Production 5,354 Units
Production Hrs. Annual 4,329
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $295,342 2,217,015 kWh $0.13
Natural Gas $1,398 68,897 MMBtu $0.02
TOTAL ENERGY COSTS $296,740
RECOMMENDED SAVINGS* $145,821 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Ancillary Material Cost One-time Revenue or Avoided Cost Electricity Usage Ancillary Material Cost One-time Revenue or Avoided Cost
$ kWh $ $ $ $
01: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$245
Cost:
$90
$245 1,885 - - - - $245
1,885
kWh
-
-
$
-
-
$
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,373
Cost:
$2,600
$6,273 48,252 $(-2,900) - - - $6,273
48,252
kWh
$(-2,900)
-
$
-
-
$
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,956
Cost:
$3,845
$1,956 15,047 - - - - $1,956
15,047
kWh
-
-
$
-
-
$
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$5,931
Cost:
$15,250
$5,931 45,627 - - - - $5,931
45,627
kWh
-
-
$
-
-
$
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$2,898
Cost:
$9,000
$2,898 22,299 - - - - $2,898
22,299
kWh
-
-
$
-
-
$
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$929
Cost:
$3,845
$929 7,143 - - - - $929
7,143
kWh
-
-
$
-
-
$
07: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$61,043
Cost:
$300,000
$25,043 192,639 - - $36,000 - $25,043
192,639
kWh
-
-
$
$36,000
-
$
08: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$69,446
Cost:
$597,013
$69,446 521,303 - - - - $69,446
521,303
kWh
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$145,821
Cost:
$931,643
$112,721 854,195 $(-2,900) - $36,000 - $112,721
854,195
kWh
$(-2,900)
-
$
$36,000
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
$
-
-
$
Savings
Cost
$ kWh $ $ $ $
Electricity Usage Ancillary Material Cost One-time Revenue or Avoided Cost Electricity Usage Ancillary Material Cost One-time Revenue or Avoided Cost