IAC logo
IAC Assessment: HO0044
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: HO0044
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Hofstra Univ.
Assessment Year 1993
Principal Product Plating Processes
NAICS n/a
SIC 2899 - Chemical Preparations, Nec
Sales $10,000,000-$50,000,000
# of Employees 100
Plant Area (Sq.Ft.) 88,000
Annual Production 0 Units
Production Hrs. Annual 2,860
Location (State) NY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $125,144 2,250,000 kWh $0.06
Natural Gas $73,007 14,871 MMBtu $4.91
TOTAL ENERGY COSTS $198,151
RECOMMENDED SAVINGS* $6,246 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,438
Cost:
$2,315
$1,438 25,791 - - $1,438
25,791
kWh
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$240
Cost:
$1,095
$240 4,396 - - $240
4,396
kWh
-
-
MMBtu
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$249
Cost:
$617
$249 4,396 - - $249
4,396
kWh
-
-
MMBtu
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$145
Cost:
$300
$145 2,638 - - $145
2,638
kWh
-
-
MMBtu
05: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$3,607
Cost:
$2,200
- - $3,607 735 -
-
kWh
$3,607
735
MMBtu
06: 2.1211 MOVE BOILER TO MORE EFFICIENT LOCATION Savings:
$567
Cost:
$274
- - $567 116 -
-
kWh
$567
116
MMBtu
TOTAL RECOMMENDED Savings:
$6,246
Cost:
$6,801
$2,072 37,221 $4,174 851 $2,072
37,221
kWh
$4,174
851
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas