Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Hofstra Univ. |
---|---|
Assessment Year | 1996 |
Principal Product | Polyester Fiber Fill |
NAICS | n/a |
SIC | 2282 - Throwing And Winding Mills |
Sales | $1,000,000-$5,000,000 |
# of Employees | 16 |
Plant Area (Sq.Ft.) | 24,000 |
Annual Production | 1,000,000 Pounds |
Production Hrs. Annual | 2,080 |
Location (State) | NY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $14,114 | 240,328 | kWh | $0.06 |
Electricity Demand | $43,055 | 1,906 | kW-months/year | $22.59 |
Electricity Fees | $3,037 | - | $ | - |
Natural Gas | $45,240 | 5,445 | MMBtu | $8.31 |
TOTAL ENERGY COSTS | $114,446 | |||
RECOMMENDED SAVINGS* | $53,427 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $53,102 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $325 Cost: $1,302 |
$103 | 1,758 | $222 | 11 | - | - | - | - |
$103 1,758 kWh |
$222 11 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $211 Cost: $905 |
$211 | 3,517 | - | - | - | - | - | - |
$211 3,517 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $96 Cost: $200 |
$96 | 1,465 | - | - | - | - | - | - |
$96 1,465 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $47,059 Cost: $145,000 |
$12,191 | 206,624 | $39,306 | 1,740 | $(-4,438) | (-1,603) | - | - |
$12,191 206,624 kWh |
$39,306 1,740 kW-months/year |
$(-4,438) (-1,603) MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $5,736 Cost: $6,500 |
- | - | - | - | - | - | $5,736 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$5,736 - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $53,427 Cost: $153,907 |
$12,601 | 213,364 | $39,528 | 1,751 | $(-4,438) | (-1,603) | $5,736 | - | $12,601 213,364 kWh |
$39,528 1,751 kW-months/year |
$(-4,438) (-1,603) MMBtu |
$5,736 - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $53,102 Cost: $152,605 |
$12,498 | 211,606 | $39,306 | 1,740 | $(-4,438) | (-1,603) | $5,736 | - | $12,498 211,606 kWh |
$39,306 1,740 kW-months/year |
$(-4,438) (-1,603) MMBtu |
$5,736 - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) |