Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Hofstra Univ. |
---|---|
Assessment Year | 1998 |
Principal Product | Roofing shingles |
NAICS | n/a |
SIC | 2952 - Asphalt Felts And Coatings |
Sales | $10,000,000-$50,000,000 |
# of Employees | 90 |
Plant Area (Sq.Ft.) | 160,000 |
Annual Production | 300,000 Thousand Feet |
Production Hrs. Annual | 8,400 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $374,973 | 7,199,004 | kWh | $0.05 |
Electricity Demand | $84,937 | 13,189 | kW-months/year | $6.44 |
Electricity Fees | $(-27,980) | - | $ | - |
Natural Gas | $525,923 | 107,827 | MMBtu | $4.88 |
TOTAL ENERGY COSTS | $1,088,163 | |||
RECOMMENDED SAVINGS* | $279,481 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $26,948 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,699 Cost: $1,772 |
$1,444 | 27,843 | $255 | 40 | - | - | - | - | - | - | - | - | - | - |
$1,444 27,843 kWh |
$255 40 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $2,998 Cost: $2,855 |
$2,998 | 57,444 | - | - | - | - | - | - | - | - | - | - | - | - |
$2,998 57,444 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $5,530 Cost: $400 |
$4,701 | 90,270 | $829 | 129 | - | - | - | - | - | - | - | - | - | - |
$4,701 90,270 kWh |
$829 129 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $26,996 Cost: $26,726 |
$22,938 | 441,383 | $4,058 | 630 | - | - | - | - | - | - | - | - | - | - |
$22,938 441,383 kWh |
$4,058 630 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $18,420 Cost: $500 |
$15,654 | 300,703 | $2,766 | 430 | - | - | - | - | - | - | - | - | - | - |
$15,654 300,703 kWh |
$2,766 430 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $23,449 Cost: $8,140 |
- | - | - | - | $23,449 | 4,805 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$23,449 4,805 MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $5,649 Cost: $1,961 |
- | - | - | - | $5,649 | 1,157 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$5,649 1,157 MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $7,031 Cost: - |
- | - | - | - | - | - | $7,031 | 9,000,000 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$7,031 9,000,000 Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.4113 TREAT AND REUSE RINSE WATERS |
Savings: $70,617 Cost: $100,000 |
- | - | - | - | - | - | $70,617 | 72,900,000 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$70,617 72,900,000 Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $52,500 Cost: $75,000 |
- | - | - | - | - | - | - | - | $60,000 | 8,000,000 | $(-7,500) | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$60,000 8,000,000 lb |
$(-7,500) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $12,000 Cost: $500 |
- | - | - | - | - | - | - | - | $12,000 | 1,600,000 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$12,000 1,600,000 lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 4.211 CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE |
Savings: $52,592 Cost: $500 |
- | - | - | - | - | - | - | - | - | - | - | - | $52,592 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
$52,592 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $279,481 Cost: $218,354 |
$47,735 | 917,643 | $7,908 | 1,229 | $29,098 | 5,962 | $77,648 | 81,900,000 | $72,000 | 9,600,000 | $(-7,500) | - | $52,592 | - | $47,735 917,643 kWh |
$7,908 1,229 kW-months/year |
$29,098 5,962 MMBtu |
$77,648 81,900,000 Tgal |
$72,000 9,600,000 lb |
$(-7,500) - $ |
$52,592 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $26,948 Cost: $3,755 |
$23,353 | 448,417 | $3,595 | 559 | - | - | - | - | - | - | - | - | - | - | $23,353 448,417 kWh |
$3,595 559 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Personnel Changes | Primary Raw Material |