Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Hofstra Univ. |
---|---|
Assessment Year | 2000 |
Principal Product | Castings |
NAICS | n/a |
SIC | 3321 - Gray And Ductile Iron Foundries |
Sales | $5,000,000-$10,000,000 |
# of Employees | 77 |
Plant Area (Sq.Ft.) | 60,000 |
Annual Production | 4,000,000 Pounds |
Production Hrs. Annual | 4,250 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $355,377 | 4,927,315 | kWh | $0.07 |
Electricity Demand | $91,137 | 21,444 | kW-months/year | $4.25 |
LPG | $14,635 | 2,797 | MMBtu | $5.23 |
Other Gas | $8,650 | 1,081 | MMBtu | $8.00 |
TOTAL ENERGY COSTS | $521,039 | |||
RECOMMENDED SAVINGS* | $94,258 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $40,524 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,727 Cost: $8,392 |
$2,338 | 32,532 | $389 | 92 | - | - | - | - | - | - |
$2,338 32,532 kWh |
$389 92 kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $15,554 Cost: $21,600 |
$15,554 | 184,936 | - | - | - | - | - | - | - | - |
$15,554 184,936 kWh |
- - kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $697 Cost: $600 |
$697 | 2,931 | - | - | - | - | - | - | - | - |
$697 2,931 kWh |
- - kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $14,666 Cost: - |
$14,666 | 174,385 | - | - | - | - | - | - | - | - |
$14,666 174,385 kWh |
- - kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $723 Cost: $4,000 |
$620 | 8,499 | $103 | 24 | - | - | - | - | - | - |
$620 8,499 kWh |
$103 24 kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $16,014 Cost: $2,700 |
- | - | $16,014 | 3,768 | - | - | - | - | - | - |
- - kWh |
$16,014 3,768 kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.322 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL |
Savings: $7,500 Cost: $5,000 |
- | - | - | - | - | - | - | - | $7,500 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - lb |
$7,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $30,000 Cost: $4,000 |
- | - | - | - | - | - | - | - | $30,000 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - lb |
$30,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.5221 RECYCLE CASTING SAND |
Savings: $5,475 Cost: $500 |
- | - | - | - | - | - | $5,475 | 600,000 | - | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$5,475 600,000 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.4155 METER WASTE WATER |
Savings: $902 Cost: - |
- | - | - | - | $902 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$902 - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $94,258 Cost: $46,792 |
$33,875 | 403,283 | $16,506 | 3,884 | $902 | - | $5,475 | 600,000 | $37,500 | - | $33,875 403,283 kWh |
$16,506 3,884 kW-months/year |
$902 - Tgal |
$5,475 600,000 lb |
$37,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $40,524 Cost: $17,492 |
$3,655 | 43,962 | $492 | 116 | $902 | - | $5,475 | 600,000 | $30,000 | - | $3,655 43,962 kWh |
$492 116 kW-months/year |
$902 - Tgal |
$5,475 600,000 lb |
$30,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | One-time Revenue or Avoided Cost |