IAC logo
IAC Assessment: IA0023
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: IA0023
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Iowa State University
Assessment Year 1992
Principal Product FROZEN VEGETABLES
NAICS n/a
SIC 2037 - Frozen Fruits And Vegetables
Sales $10,000,000-$50,000,000
# of Employees 300
Plant Area (Sq.Ft.) 0
Annual Production 50,000,000 Pounds
Production Hrs. Annual 4,296
Location (State) MN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $861,190 12,551,876 kWh $0.07
Natural Gas $20,852 5,887 MMBtu $3.54
TOTAL ENERGY COSTS $882,042
RECOMMENDED SAVINGS* $453,900 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE Savings:
$136,664
Cost:
$13,000
$136,664 1,991,794 - - - - $136,664
1,991,794
kWh
-
-
MMBtu
-
-
$
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,994
Cost:
$16
$1,994 29,015 - - - - $1,994
29,015
kWh
-
-
MMBtu
-
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,957
Cost:
$1,480
$4,715 68,581 - - $(-1,758) - $4,715
68,581
kWh
-
-
MMBtu
$(-1,758)
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,986
Cost:
$8,825
$3,986 58,030 - - - - $3,986
58,030
kWh
-
-
MMBtu
-
-
$
05: 2.6232 INSTALL SET-BACK TIMERS Savings:
$1,114
Cost:
$1,188
$1,114 16,120 - - - - $1,114
16,120
kWh
-
-
MMBtu
-
-
$
06: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$1,709
Cost:
$8,000
$1,709 24,912 - - - - $1,709
24,912
kWh
-
-
MMBtu
-
-
$
07: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$94,150
Cost:
$84,875
$94,150 - - - - - $94,150
-
kWh
-
-
MMBtu
-
-
$
08: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT Savings:
$211,326
Cost:
$1
$485,573 7,806,858 $(-157,145) (-74,831) $(-117,102) - $485,573
7,806,858
kWh
$(-157,145)
(-74,831)
MMBtu
$(-117,102)
-
$
TOTAL RECOMMENDED Savings:
$453,900
Cost:
$117,385
$729,905 9,995,310 $(-157,145) (-74,831) $(-118,860) - $729,905
9,995,310
kWh
$(-157,145)
(-74,831)
MMBtu
$(-118,860)
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes