IAC Center | Iowa State University |
---|---|
Assessment Year | 1997 |
Principal Product | Industrial Laminates |
NAICS | n/a |
SIC | 3083 - Laminated Plastics Plate & Sheet |
Sales | $10,000,000-$50,000,000 |
# of Employees | 125 |
Plant Area (Sq.Ft.) | 113,000 |
Annual Production | 12,000,000 Pounds |
Production Hrs. Annual | 6,000 |
Location (State) | IA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $130,694 | 5,107,855 | kWh | $0.03 |
Electricity Demand | $71,838 | 11,076 | kW-months/year | $6.49 |
Natural Gas | $380,414 | 146,970 | MMBtu | $2.59 |
TOTAL ENERGY COSTS | $594,009 | |||
RECOMMENDED SAVINGS* | $115,024 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $6,325 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Primary Raw Material | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Primary Raw Material | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.4115 RECOVER AND REUSE COOLING WATER |
Savings: $99,165 Cost: $105,000 |
$(-3,556) | (-136,870) | $(-2,726) | (-428) | - | - | - | - | $105,447 | - |
$(-3,556) (-136,870) kWh |
$(-2,726) (-428) kW-months/year |
- - MMBtu |
- - $ |
$105,447 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7313 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING |
Savings: $5,284 Cost: $4,100 |
$883 | 33,998 | $1,239 | 161 | $3,162 | 1,221 | - | - | - | - |
$883 33,998 kWh |
$1,239 161 kW-months/year |
$3,162 1,221 MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $4,119 Cost: $5,200 |
$2,668 | 102,579 | $1,451 | 228 | - | - | - | - | - | - |
$2,668 102,579 kWh |
$1,451 228 kW-months/year |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.8121 COVER CONTAINERS TO MINIMIZE EVAPORATIVE LOSSES |
Savings: $4,250 Cost: $6,300 |
- | - | - | - | - | - | $4,250 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$4,250 - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $475 Cost: $592 |
$319 | 12,309 | $156 | 24 | - | - | - | - | - | - |
$319 12,309 kWh |
$156 24 kW-months/year |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $804 Cost: $1,705 |
$537 | 20,516 | $267 | 42 | - | - | - | - | - | - |
$537 20,516 kWh |
$267 42 kW-months/year |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $488 Cost: $538 |
$320 | 12,309 | $168 | 26 | - | - | - | - | - | - |
$320 12,309 kWh |
$168 26 kW-months/year |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $325 Cost: $139 |
$218 | 8,499 | $107 | 17 | - | - | - | - | - | - |
$218 8,499 kWh |
$107 17 kW-months/year |
- - MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $114 Cost: $176 |
- | - | - | - | $114 | 44 | - | - | - | - |
- - kWh |
- - kW-months/year |
$114 44 MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $115,024 Cost: $123,750 |
$1,389 | 53,340 | $662 | 70 | $3,276 | 1,265 | $4,250 | - | $105,447 | - | $1,389 53,340 kWh |
$662 70 kW-months/year |
$3,276 1,265 MMBtu |
$4,250 - $ |
$105,447 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $6,325 Cost: $8,350 |
$4,062 | 156,212 | $2,149 | 337 | $114 | 44 | - | - | - | - | $4,062 156,212 kWh |
$2,149 337 kW-months/year |
$114 44 MMBtu |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Primary Raw Material | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Primary Raw Material | Water Consumption |