Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Iowa State University
Assessment Year 1998
Principal Product surgical and dust masks
NAICS n/a
SIC 3842 - Surgical Appliances And Supplies
Sales $100,000,000-$500,000,000
# of Employees 400
Plant Area (Sq.Ft.) 235,000
Annual Production 10,000,000 Pounds
Production Hrs. Annual 8,736
Location (State) NE
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $501,334 22,163,541 kWh $0.02
Electricity Demand $315,029 46,392 kW-months/year $6.79
Natural Gas $47,334 10,998 MMBtu $4.30
TOTAL ENERGY COSTS $994,987
RECOMMENDED SAVINGS* $279,744 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $11,495
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes Electricity Usage Electricity Demand Natural Gas Personnel Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,138
Cost:
$17,423
$3,631 161,489 $1,507 222 - - - - $3,631
161,489
kWh
$1,507
222
kW-months/year
-
-
MMBtu
-
-
$
02: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING Savings:
$4,040
Cost:
$12,186
$4,040 211,313 - - - - - - $4,040
211,313
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$2,457
Cost:
$2,793
$2,457 109,320 - - - - - - $2,457
109,320
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,766
Cost:
$4,820
$2,675 118,992 $1,091 161 - - - - $2,675
118,992
kWh
$1,091
161
kW-months/year
-
-
MMBtu
-
-
$
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$134
Cost:
$282
$95 4,396 $39 6 - - - - $95
4,396
kWh
$39
6
kW-months/year
-
-
MMBtu
-
-
$
06: 4.423 MOVE PRODUCT USING MECHANICAL MEANS Savings:
$261,385
Cost:
$19,800
$(-491) (-21,981) $(-204) (-30) - - $262,080 - $(-491)
(-21,981)
kWh
$(-204)
(-30)
kW-months/year
-
-
MMBtu
$262,080
-
$
07: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$2,824
Cost:
$10,101
$4,198 186,401 - - $(-1,374) (-319) - - $4,198
186,401
kWh
-
-
kW-months/year
$(-1,374)
(-319)
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$279,744
Cost:
$67,405
$16,605 769,930 $2,433 359 $(-1,374) (-319) $262,080 - $16,605
769,930
kWh
$2,433
359
kW-months/year
$(-1,374)
(-319)
MMBtu
$262,080
-
$
TOTAL IMPLEMENTED Savings:
$11,495
Cost:
$25,318
$8,858 394,197 $2,637 389 - - - - $8,858
394,197
kWh
$2,637
389
kW-months/year
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Personnel Changes Electricity Usage Electricity Demand Natural Gas Personnel Changes