Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Iowa State University |
---|---|
Assessment Year | 1998 |
Principal Product | surgical and dust masks |
NAICS | n/a |
SIC | 3842 - Surgical Appliances And Supplies |
Sales | $100,000,000-$500,000,000 |
# of Employees | 400 |
Plant Area (Sq.Ft.) | 235,000 |
Annual Production | 10,000,000 Pounds |
Production Hrs. Annual | 8,736 |
Location (State) | NE |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $501,334 | 22,163,541 | kWh | $0.02 |
Electricity Demand | $315,029 | 46,392 | kW-months/year | $6.79 |
Natural Gas | $47,334 | 10,998 | MMBtu | $4.30 |
TOTAL ENERGY COSTS | $994,987 | |||
RECOMMENDED SAVINGS* | $279,744 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $11,495 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,138 Cost: $17,423 |
$3,631 | 161,489 | $1,507 | 222 | - | - | - | - |
$3,631 161,489 kWh |
$1,507 222 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $4,040 Cost: $12,186 |
$4,040 | 211,313 | - | - | - | - | - | - |
$4,040 211,313 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,457 Cost: $2,793 |
$2,457 | 109,320 | - | - | - | - | - | - |
$2,457 109,320 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,766 Cost: $4,820 |
$2,675 | 118,992 | $1,091 | 161 | - | - | - | - |
$2,675 118,992 kWh |
$1,091 161 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $134 Cost: $282 |
$95 | 4,396 | $39 | 6 | - | - | - | - |
$95 4,396 kWh |
$39 6 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.423 MOVE PRODUCT USING MECHANICAL MEANS |
Savings: $261,385 Cost: $19,800 |
$(-491) | (-21,981) | $(-204) | (-30) | - | - | $262,080 | - |
$(-491) (-21,981) kWh |
$(-204) (-30) kW-months/year |
- - MMBtu |
$262,080 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $2,824 Cost: $10,101 |
$4,198 | 186,401 | - | - | $(-1,374) | (-319) | - | - |
$4,198 186,401 kWh |
- - kW-months/year |
$(-1,374) (-319) MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $279,744 Cost: $67,405 |
$16,605 | 769,930 | $2,433 | 359 | $(-1,374) | (-319) | $262,080 | - | $16,605 769,930 kWh |
$2,433 359 kW-months/year |
$(-1,374) (-319) MMBtu |
$262,080 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $11,495 Cost: $25,318 |
$8,858 | 394,197 | $2,637 | 389 | - | - | - | - | $8,858 394,197 kWh |
$2,637 389 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |