Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Iowa State University |
---|---|
Assessment Year | 2006 |
Principal Product | ham, sausage, bacon |
NAICS | 311612 - Meat Processed from Carcasses |
SIC | 2013 - Sausages And Other Prepared Meats |
Sales | $5,000,000-$10,000,000 |
# of Employees | 94 |
Plant Area (Sq.Ft.) | 70,000 |
Annual Production | 5,800,000 Pounds |
Production Hrs. Annual | 2,959 |
Location (State) | IA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $106,878 | 2,163,657 | kWh | $0.05 |
Electricity Demand | $29,400 | 5,424 | kW-months/year | $5.42 |
Electricity Fees | $1,581 | - | $ | - |
TOTAL ENERGY COSTS | $171,636 | |||
RECOMMENDED SAVINGS* | $54,783 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,283 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $336 Cost: $25 |
$232 | 4,374 | $104 | 19 | - | - | - | - | - | - | - | - |
$232 4,374 kWh |
$104 19 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $685 Cost: $215 |
$471 | 9,617 | $214 | 40 | - | - | - | - | - | - | - | - |
$471 9,617 kWh |
$214 40 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $262 Cost: $879 |
$213 | 4,343 | $49 | 9 | - | - | - | - | - | - | - | - |
$213 4,343 kWh |
$49 9 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,513 Cost: $8,142 |
$2,801 | 56,975 | $712 | 130 | - | - | - | - | - | - | - | - |
$2,801 56,975 kWh |
$712 130 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,037 Cost: $1,906 |
$2,432 | 49,999 | $605 | 112 | - | - | - | - | - | - | - | - |
$2,432 49,999 kWh |
$605 112 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION |
Savings: $11,632 Cost: $4,000 |
- | - | - | - | - | - | $7,368 | 1,469,700 | - | - | $4,264 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$7,368 1,469,700 Tgal |
- - $ |
$4,264 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.4154 ELIMINATE LEAKS IN WATER LINES AND VALVES |
Savings: $298 Cost: $650 |
- | - | - | - | - | - | $189 | 37,677 | - | - | $109 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$189 37,677 Tgal |
- - $ |
$109 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $35,020 Cost: $29,000 |
- | - | - | - | $5,430 | 725 | - | - | $29,590 | - | - | - |
- - kWh |
- - kW-months/year |
$5,430 725 MMBtu |
- - Tgal |
$29,590 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $54,783 Cost: $44,817 |
$6,149 | 125,308 | $1,684 | 310 | $5,430 | 725 | $7,557 | 1,507,377 | $29,590 | - | $4,373 | - | $6,149 125,308 kWh |
$1,684 310 kW-months/year |
$5,430 725 MMBtu |
$7,557 1,507,377 Tgal |
$29,590 - $ |
$4,373 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,283 Cost: $1,119 |
$916 | 18,334 | $367 | 68 | - | - | - | - | - | - | - | - | $916 18,334 kWh |
$367 68 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Water Consumption |