Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Iowa State University |
---|---|
Assessment Year | 2006 |
Principal Product | Hog confinement products |
NAICS | 332311 - Prefabricated Metal Building and Component Manufacturing |
SIC | 3448 - Prefabricated Metal Buildings |
Sales | $5,000,000-$10,000,000 |
# of Employees | 88 |
Plant Area (Sq.Ft.) | 98,000 |
Annual Production | 12,750,000 Pounds |
Production Hrs. Annual | 2,340 |
Location (State) | IA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $31,001 | 915,080 | kWh | $0.03 |
Electricity Demand | $57,163 | 6,372 | kW-months/year | $8.97 |
Natural Gas | $77,378 | 9,521 | MMBtu | $8.13 |
TOTAL ENERGY COSTS | $165,542 | |||
RECOMMENDED SAVINGS* | $199,070 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $12,276 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,747 Cost: $276 |
$2,271 | 67,850 | $1,476 | 173 | - | - | - | - |
$2,271 67,850 kWh |
$1,476 173 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,621 Cost: $15 |
$1,588 | 47,268 | $1,033 | 121 | - | - | - | - |
$1,588 47,268 kWh |
$1,033 121 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $5,908 Cost: $4 |
$3,577 | 106,470 | $2,331 | 274 | - | - | - | - |
$3,577 106,470 kWh |
$2,331 274 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $384 Cost: $706 |
$167 | 4,959 | $217 | 2 | - | - | - | - |
$167 4,959 kWh |
$217 2 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,134 Cost: $2,420 |
$461 | 13,782 | $673 | 80 | - | - | - | - |
$461 13,782 kWh |
$673 80 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $9,538 Cost: $57,500 |
$3,608 | 107,392 | $5,930 | 58 | - | - | - | - |
$3,608 107,392 kWh |
$5,930 58 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $229 Cost: $433 |
- | - | - | - | $229 | 28 | - | - |
- - kWh |
- - kW-months/year |
$229 28 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $327 Cost: $134 |
$156 | 3,109 | $171 | 1 | - | - | - | - |
$156 3,109 kWh |
$171 1 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2312 MINIMIZE NON-ESSENTIAL MATERIAL IN HEAT TREATMENT PROCESS |
Savings: $1,682 Cost: $7,200 |
$(-1,254) | (-37,323) | $(-1,630) | (-16) | $4,566 | 562 | - | - |
$(-1,254) (-37,323) kWh |
$(-1,630) (-16) kW-months/year |
$4,566 562 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.112 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL |
Savings: $173,500 Cost: $190,000 |
- | - | - | - | - | - | $173,500 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$173,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $199,070 Cost: $258,688 |
$10,574 | 313,507 | $10,201 | 693 | $4,795 | 590 | $173,500 | - | $10,574 313,507 kWh |
$10,201 693 kW-months/year |
$4,795 590 MMBtu |
$173,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $12,276 Cost: $295 |
$7,436 | 221,588 | $4,840 | 568 | - | - | - | - | $7,436 221,588 kWh |
$4,840 568 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |