Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Illinois, Chicago |
---|---|
Assessment Year | 2001 |
Principal Product | Ball Bearings |
NAICS | n/a |
SIC | 3562 - Ball And Roller Bearings |
Sales | $10,000,000-$50,000,000 |
# of Employees | 60 |
Plant Area (Sq.Ft.) | 54,500 |
Annual Production | 22,000,000 Pieces |
Production Hrs. Annual | 7,488 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $199,524 | 5,351,729 | kWh | $0.04 |
Electricity Demand | $115,306 | 9,407 | kW-months/year | $12.26 |
Electricity Fees | $20,817 | - | $ | - |
Natural Gas | $18,049 | 2,666 | MMBtu | $6.77 |
TOTAL ENERGY COSTS | $403,471 | |||
RECOMMENDED SAVINGS* | $411,942 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $86,973 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $7,018 Cost: $5,950 |
$4,597 | 123,245 | $2,421 | 16 | - | - | - | - |
$4,597 123,245 kWh |
$2,421 16 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,969 Cost: $3,000 |
$2,601 | 69,733 | $1,368 | 112 | - | - | - | - |
$2,601 69,733 kWh |
$1,368 112 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,974 Cost: $29,136 |
$4,428 | 118,717 | $2,546 | 208 | - | - | - | - |
$4,428 118,717 kWh |
$2,546 208 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,411 Cost: $3,500 |
$834 | 22,355 | $1,577 | 129 | - | - | - | - |
$834 22,355 kWh |
$1,577 129 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $5,570 Cost: $10,600 |
$759 | 20,351 | $4,811 | 392 | - | - | - | - |
$759 20,351 kWh |
$4,811 392 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.322 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL |
Savings: $300,000 Cost: $8,500 |
- | - | - | - | - | - | $300,000 | - |
- - kWh |
- - kW-months/year |
- - $ |
$300,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.426 MODIFY WORKLOAD |
Savings: $65,000 Cost: $5,500 |
- | - | - | - | $48,000 | - | $17,000 | - |
- - kWh |
- - kW-months/year |
$48,000 - $ |
$17,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.441 INSTALL AUTOMATIC PACKING EQUIPMENT |
Savings: $21,000 Cost: $53,000 |
- | - | - | - | $21,000 | - | - | - |
- - kWh |
- - kW-months/year |
$21,000 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $411,942 Cost: $119,186 |
$13,219 | 354,401 | $12,723 | 857 | $69,000 | - | $317,000 | - | $13,219 354,401 kWh |
$12,723 857 kW-months/year |
$69,000 - $ |
$317,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $86,973 Cost: $54,686 |
$10,618 | 284,668 | $11,355 | 745 | $48,000 | - | $17,000 | - | $10,618 284,668 kWh |
$11,355 745 kW-months/year |
$48,000 - $ |
$17,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes |