Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Illinois, Chicago |
---|---|
Assessment Year | 2008 |
Principal Product | Raw Materials |
NAICS | 332991 - Ball and Roller Bearing Manufacturing |
SIC | 3562 - Ball And Roller Bearings |
Sales | $1,000,000-$5,000,000 |
# of Employees | 130 |
Plant Area (Sq.Ft.) | 242,088 |
Annual Production | 245,000 Pieces |
Production Hrs. Annual | 3,428 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $145,071 | 2,293,080 | kWh | $0.06 |
Electricity Demand | $53,389 | 5,010 | kW-months/year | $10.66 |
Natural Gas | $101,871 | 13,596 | MMBtu | $7.49 |
TOTAL ENERGY COSTS | $308,387 | |||
RECOMMENDED SAVINGS* | $77,662 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $57,047 Cost: $112,631 |
$38,445 | 610,231 | $20,329 | 1,907 | - | - | $(-1,658) | - | $(-69) | - |
$38,445 610,231 kWh |
$20,329 1,907 kW-months/year |
- - MMBtu |
$(-1,658) - $ |
$(-69) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $556 Cost: $4,664 |
$311 | 4,913 | $182 | 17 | - | - | - | - | $63 | - |
$311 4,913 kWh |
$182 17 kW-months/year |
- - MMBtu |
- - $ |
$63 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,604 Cost: $14,300 |
$3,106 | 49,291 | $2,147 | 201 | - | - | $129 | - | $(-778) | - |
$3,106 49,291 kWh |
$2,147 201 kW-months/year |
- - MMBtu |
$129 - $ |
$(-778) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,134 Cost: $391 |
$569 | 9,024 | $416 | 39 | - | - | $172 | - | $(-23) | - |
$569 9,024 kWh |
$416 39 kW-months/year |
- - MMBtu |
$172 - $ |
$(-23) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $7,958 Cost: $14,655 |
$4,813 | 76,396 | $3,145 | 295 | - | - | - | - | - | - |
$4,813 76,396 kWh |
$3,145 295 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $466 Cost: $3,785 |
$242 | 3,842 | $224 | 21 | - | - | - | - | - | - |
$242 3,842 kWh |
$224 21 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.811 DEMOLISH OLD BUILDING TO REDUCE TAX AND INSURANCE BILLS |
Savings: $2,172 Cost: $4,500 |
- | - | - | - | $2,172 | 270 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,172 270 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.512 CONDENSE OPERATION INTO ONE BUILDING |
Savings: $3,114 Cost: - |
$508 | 8,072 | $416 | 39 | $2,082 | 276 | $108 | - | - | - |
$508 8,072 kWh |
$416 39 kW-months/year |
$2,082 276 MMBtu |
$108 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $611 Cost: - |
$227 | 3,600 | $384 | 36 | - | - | - | - | - | - |
$227 3,600 kWh |
$384 36 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $77,662 Cost: $154,926 |
$48,221 | 765,369 | $27,243 | 2,555 | $4,254 | 546 | $(-1,249) | - | $(-807) | - | $48,221 765,369 kWh |
$27,243 2,555 kW-months/year |
$4,254 546 MMBtu |
$(-1,249) - $ |
$(-807) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||