Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Illinois, Chicago |
---|---|
Assessment Year | 2011 |
Principal Product | Publication Printing and Binding |
NAICS | 323111 - Commercial Printing (except Screen and Books) |
SIC | 2752 - Commercial Printing, Lithographic |
Sales | $100,000,000-$500,000,000 |
# of Employees | 640 |
Plant Area (Sq.Ft.) | 600,000 |
Annual Production | 52,000,000 Units |
Production Hrs. Annual | 8,424 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $2,562,500 | 48,922,817 | kWh | $0.05 |
Electricity Demand | $46,196 | 8,069 | kW-months/year | $5.73 |
Natural Gas | $904,481 | 179,114 | MMBtu | $5.05 |
TOTAL ENERGY COSTS | $3,575,737 | |||
RECOMMENDED SAVINGS* | $360,321 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $29,203 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Gaseous Waste | Electricity Usage | Electricity Demand | Natural Gas | Gaseous Waste | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $265,693 Cost: $277,838 |
$342,941 | 6,595,001 | $51,767 | 9,034 | $(-129,015) | (-25,548) | - | - |
$342,941 6,595,001 kWh |
$51,767 9,034 kW-months/year |
$(-129,015) (-25,548) MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $8,671 Cost: $21,422 |
$7,495 | 144,184 | $1,176 | 205 | - | - | - | - |
$7,495 144,184 kWh |
$1,176 205 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $11,196 Cost: $20,077 |
$9,651 | 185,409 | $1,545 | 269 | - | - | - | - |
$9,651 185,409 kWh |
$1,545 269 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $4,215 Cost: $5,303 |
$3,628 | 69,743 | $587 | 103 | - | - | - | - |
$3,628 69,743 kWh |
$587 103 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $3,121 Cost: $3,748 |
- | - | - | - | $3,121 | 618 | - | - |
- - kWh |
- - kW-months/year |
$3,121 618 MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $2,000 Cost: $7,588 |
- | - | - | - | $2,000 | 396 | - | - |
- - kWh |
- - kW-months/year |
$2,000 396 MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7312 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE |
Savings: $65,425 Cost: $345,000 |
$(-64,311) | (-1,236,733) | $(-10,177) | (-1,776) | - | - | $139,913 | 3,610,000,000 |
$(-64,311) (-1,236,733) kWh |
$(-10,177) (-1,776) kW-months/year |
- - MMBtu |
$139,913 3,610,000,000 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $360,321 Cost: $680,976 |
$299,404 | 5,757,604 | $44,898 | 7,835 | $(-123,894) | (-24,534) | $139,913 | 3,610,000,000 | $299,404 5,757,604 kWh |
$44,898 7,835 kW-months/year |
$(-123,894) (-24,534) MMBtu |
$139,913 3,610,000,000 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $29,203 Cost: $58,138 |
$20,774 | 399,336 | $3,308 | 577 | $5,121 | 1,014 | - | - | $20,774 399,336 kWh |
$3,308 577 kW-months/year |
$5,121 1,014 MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Gaseous Waste | Electricity Usage | Electricity Demand | Natural Gas | Gaseous Waste |