IAC logo
IAC Assessment: IC0188
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: IC0188
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Illinois, Chicago
Assessment Year 2011
Principal Product batteries
NAICS 335911 - Storage Battery Manufacturing
SIC 3691 - Storage Batteries
Sales $1,000,000-$5,000,000
# of Employees 287
Plant Area (Sq.Ft.) 275,000
Annual Production 1,700 Pieces
Production Hrs. Annual 1,992
Location (State) IN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $519,271 17,633,250 kWh $0.03
Electricity Demand $53,649 2,737 kW-months/year $19.60
Electricity Fees $17,138 - $ -
Natural Gas $575,767 100,723 MMBtu $5.72
TOTAL ENERGY COSTS $1,179,825
RECOMMENDED SAVINGS* $40,824 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost
$ kWh $ kW-months/year $ $ $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$20,742
Cost:
$44,268
$7,551 260,431 $13,216 674 $(-619) - $594 - $7,551
260,431
kWh
$13,216
674
kW-months/year
$(-619)
-
$
$594
-
$
02: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$244
Cost:
$541
$48 1,657 $196 10 - - - - $48
1,657
kWh
$196
10
kW-months/year
-
-
$
-
-
$
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$9,096
Cost:
-
$9,096 324,864 - - - - - - $9,096
324,864
kWh
-
-
kW-months/year
-
-
$
-
-
$
04: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$285
Cost:
-
$148 5,100 $137 7 - - - - $148
5,100
kWh
$137
7
kW-months/year
-
-
$
-
-
$
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$422
Cost:
-
$83 2,871 $339 17 - - - - $83
2,871
kWh
$339
17
kW-months/year
-
-
$
-
-
$
06: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$3,582
Cost:
$690
$3,582 123,510 - - - - - - $3,582
123,510
kWh
-
-
kW-months/year
-
-
$
-
-
$
07: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$6,453
Cost:
-
- - $6,453 329 - - - - -
-
kWh
$6,453
329
kW-months/year
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$40,824
Cost:
$45,499
$20,508 718,433 $20,341 1,037 $(-619) - $594 - $20,508
718,433
kWh
$20,341
1,037
kW-months/year
$(-619)
-
$
$594
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $
Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost