Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Illinois, Chicago
Assessment Year 2017
Principal Product Wastewater Treatment Facility
NAICS 221320 - Sewage Treatment Facilities
SIC 4952 - Sewerage Systems
Sales <$500,000
# of Employees 84
Plant Area (Sq.Ft.) 200,000
Annual Production 24,687,728 Pounds
Production Hrs. Annual 8,760
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,366,236 20,984,569 kWh $0.07
Electricity Demand $33,098 3,102 kW-months/year $10.67
Electricity Fees $0 - $ -
Natural Gas $146,138 21,100 MMBtu $6.93
TOTAL ENERGY COSTS $1,545,472
RECOMMENDED SAVINGS* $139,874 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $84,038
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$79,158
Cost:
$193,800
$66,994 788,171 $12,164 1,140 $66,994
788,171
kWh
$12,164
1,140
kW-months/year
02: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$53,319
Cost:
$1,029,975
$53,319 627,283 - - $53,319
627,283
kWh
-
-
kW-months/year
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,932
Cost:
$14,716
$2,280 26,832 $1,652 155 $2,280
26,832
kWh
$1,652
155
kW-months/year
04: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$2,517
Cost:
$7,106
$2,517 29,603 - - $2,517
29,603
kWh
-
-
kW-months/year
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$948
Cost:
$1,847
$551 6,448 $397 37 $551
6,448
kWh
$397
37
kW-months/year
TOTAL RECOMMENDED Savings:
$139,874
Cost:
$1,247,444
$125,661 1,478,337 $14,213 1,332 $125,661
1,478,337
kWh
$14,213
1,332
kW-months/year
TOTAL IMPLEMENTED Savings:
$84,038
Cost:
$210,363
$69,825 821,451 $14,213 1,332 $69,825
821,451
kWh
$14,213
1,332
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand