Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Illinois, Chicago |
---|---|
Assessment Year | 2025 |
Principal Product | Wastewater Treatment |
NAICS | 221320 - Sewage Treatment Facilities |
SIC | 4952 - Sewerage Systems |
Sales | <$500,000 |
# of Employees | 66 |
Plant Area (Sq.Ft.) | 3,090,929 |
Annual Production | 7,304,850 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $954,069 | 14,919,671 | kWh | $0.06 |
Electricity Demand | $92,857 | 28,892 | kW-months/year | $3.21 |
Electricity Fees | $229,530 | - | $ | - |
Natural Gas | $149,278 | 13,150 | MMBtu | $11.35 |
Other Gas | $1,622,009 | 1,109,298 | MMBtu | $1.46 |
TOTAL ENERGY COSTS | $3,047,743 | |||
RECOMMENDED SAVINGS* | $3,862,625 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Gas | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Gas | Ancillary Material Cost | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $11,344 Cost: $4,184 |
- | - | - | - | $11,344 | 995 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$11,344 995 MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,649 Cost: $4,909 |
$5,295 | 82,732 | $354 | 113 | - | - | - | - | - | - | - | - |
$5,295 82,732 kWh |
$354 113 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $833 Cost: $781 |
$602 | 9,404 | $231 | 72 | - | - | - | - | - | - | - | - |
$602 9,404 kWh |
$231 72 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1336 INSTALL EQUIPMENT TO UTILIZE WASTE FUEL |
Savings: $1,776,306 Cost: $9,581,351 |
- | - | - | - | $(-480,715) | (-42,168) | $73,783 | 50,467 | $(-166,632) | - | $2,349,870 | - |
- - kWh |
- - kW-months/year |
$(-480,715) (-42,168) MMBtu |
$73,783 50,467 MMBtu |
$(-166,632) - $ |
$2,349,870 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $6,255 Cost: $8,951 |
$6,192 | 96,708 | $63 | 20 | - | - | - | - | - | - | - | - |
$6,192 96,708 kWh |
$63 20 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1224 REPLACE BOILER |
Savings: $133,316 Cost: $376,143 |
- | - | - | - | $133,316 | 11,694 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$133,316 11,694 MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,756 Cost: $391 |
$2,401 | 37,516 | $355 | 110 | - | - | - | - | - | - | - | - |
$2,401 37,516 kWh |
$355 110 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $688 Cost: $63 |
$301 | 4,702 | $387 | 124 | - | - | - | - | - | - | - | - |
$301 4,702 kWh |
$387 124 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $62,936 Cost: $159,045 |
$56,748 | 886,690 | $6,188 | 1,980 | - | - | - | - | - | - | - | - |
$56,748 886,690 kWh |
$6,188 1,980 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $74,545 Cost: $10,174 |
$68,756 | 1,074,313 | $5,789 | 1,801 | - | - | - | - | - | - | - | - |
$68,756 1,074,313 kWh |
$5,789 1,801 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,250 Cost: $1,159 |
$1,170 | 18,282 | $80 | 25 | - | - | - | - | - | - | - | - |
$1,170 18,282 kWh |
$80 25 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.9141 Install Anaerobic Digester |
Savings: $1,786,748 Cost: $9,930,710 |
- | - | - | - | $(-469,548) | (-41,188) | $74,796 | 51,160 | $(-168,370) | - | $2,349,870 | - |
- - kWh |
- - kW-months/year |
$(-469,548) (-41,188) MMBtu |
$74,796 51,160 MMBtu |
$(-168,370) - $ |
$2,349,870 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $3,862,625 Cost: $20,077,861 |
$141,465 | 2,210,347 | $13,446 | 4,245 | $(-805,603) | (-70,667) | $148,579 | 101,627 | $(-335,002) | - | $4,699,740 | - | $141,465 2,210,347 kWh |
$13,446 4,245 kW-months/year |
$(-805,603) (-70,667) MMBtu |
$148,579 101,627 MMBtu |
$(-335,002) - $ |
$4,699,740 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Gas | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Gas | Ancillary Material Cost | One-time Revenue or Avoided Cost |