Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Illinois, Chicago
Assessment Year 2025
Principal Product Flavored Popcorn
NAICS 311919 - Other Snack Food Manufacturing
SIC 2096 - Potato Chips And Similar Snacks
Sales $10,000,000-$50,000,000
# of Employees 87
Plant Area (Sq.Ft.) 145,000
Annual Production 6,000,000 Pounds
Production Hrs. Annual 6,240
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $143,497 1,473,532 kWh $0.10
Electricity Demand $45,941 3,865 kW-months/year $11.89
Electricity Fees $6,617 - $ -
Natural Gas $102,578 12,854 MMBtu $7.98
TOTAL ENERGY COSTS $298,633
RECOMMENDED SAVINGS* $144,700 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$693
Cost:
$644
$462 4,758 $231 19 - - $462
4,758
kWh
$231
19
kW-months/year
-
-
MMBtu
02: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$93,480
Cost:
$390,298
$53,874 555,402 $39,606 3,331 - - $53,874
555,402
kWh
$39,606
3,331
kW-months/year
-
-
MMBtu
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$730
Cost:
$1,774
$591 6,093 $139 12 - - $591
6,093
kWh
$139
12
kW-months/year
-
-
MMBtu
04: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$4,867
Cost:
-
- - $4,867 409 - - -
-
kWh
$4,867
409
kW-months/year
-
-
MMBtu
05: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$1,027
Cost:
$1,211
$1,027 10,585 - - - - $1,027
10,585
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.2427 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS Savings:
$12,206
Cost:
$5,047
- - - - $12,206 1,530 -
-
kWh
-
-
kW-months/year
$12,206
1,530
MMBtu
07: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$7,389
Cost:
$352
- - - - $7,389 926 -
-
kWh
-
-
kW-months/year
$7,389
926
MMBtu
08: 2.2511 INSULATE BARE EQUIPMENT Savings:
$19,153
Cost:
$1,152
- - - - $19,153 2,400 -
-
kWh
-
-
kW-months/year
$19,153
2,400
MMBtu
09: 2.2511 INSULATE BARE EQUIPMENT Savings:
$2,006
Cost:
$701
- - - - $2,006 251 -
-
kWh
-
-
kW-months/year
$2,006
251
MMBtu
10: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$2,444
Cost:
-
$2,397 24,710 $47 4 - - $2,397
24,710
kWh
$47
4
kW-months/year
-
-
MMBtu
11: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$706
Cost:
$565
$418 4,313 $288 24 - - $418
4,313
kWh
$288
24
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$144,700
Cost:
$401,744
$58,769 605,861 $45,178 3,800 $40,754 5,107 $58,769
605,861
kWh
$45,178
3,800
kW-months/year
$40,754
5,107
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas