Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Indiana University-Purdue University |
---|---|
Assessment Year | 2015 |
Principal Product | Tube Cutoff Machines |
NAICS | 333249 - Other Industrial Machinery Manufacturing |
SIC | 3559 - Special Industry Machinery, Nec |
Sales | $1,000,000-$5,000,000 |
# of Employees | 13 |
Plant Area (Sq.Ft.) | 47,000 |
Annual Production | 10 Pieces |
Production Hrs. Annual | 2,340 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $10,940 | 204,792 | kWh | $0.05 |
Electricity Demand | $14,050 | 1,014 | kW-months/year | $13.86 |
Electricity Fees | $2,268 | - | $ | - |
LPG | $34,978 | 1,314 | MMBtu | $26.63 |
TOTAL ENERGY COSTS | $62,236 | |||
RECOMMENDED SAVINGS* | $33,231 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $33,231 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | LPG | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | LPG | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.812 APPLY FOR INVESTMENT INCENTIVES |
Savings: $1,605 Cost: - |
- | - | - | - | $1,605 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,605 - $ |
- - MMBtu |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $401 Cost: - |
$171 | 3,227 | $230 | 17 | - | - | - | - | - | - |
$171 3,227 kWh |
$230 17 kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1331 BURN A LESS EXPENSIVE GRADE OF FUEL |
Savings: $25,783 Cost: $1,054 |
- | - | - | - | - | - | $(-9,195) | (-1,314) | $34,978 | 1,314 |
- - kWh |
- - kW-months/year |
- - $ |
$(-9,195) (-1,314) MMBtu |
$34,978 1,314 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,242 Cost: $417 |
$530 | 10,006 | $711 | 48 | - | - | - | - | - | - |
$530 10,006 kWh |
$711 48 kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $4,201 Cost: $17,250 |
- | - | - | - | - | - | - | - | $4,201 | 163 |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$4,201 163 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $33,231 Cost: $18,721 |
$701 | 13,233 | $941 | 65 | $1,605 | - | $(-9,195) | (-1,314) | $39,179 | 1,476 | $701 13,233 kWh |
$941 65 kW-months/year |
$1,605 - $ |
$(-9,195) (-1,314) MMBtu |
$39,179 1,476 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $33,231 Cost: $18,721 |
$701 | 13,233 | $941 | 65 | $1,605 | - | $(-9,195) | (-1,314) | $39,179 | 1,476 | $701 13,233 kWh |
$941 65 kW-months/year |
$1,605 - $ |
$(-9,195) (-1,314) MMBtu |
$39,179 1,476 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | LPG | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | LPG |