Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Indiana University-Purdue University |
---|---|
Assessment Year | 2016 |
Principal Product | Spinal Implants/Medical Devices |
NAICS | 339112 - Surgical and Medical Instrument Manufacturing |
SIC | 3842 - Surgical Appliances And Supplies |
Sales | $100,000,000-$500,000,000 |
# of Employees | 500 |
Plant Area (Sq.Ft.) | 150,000 |
Annual Production | 1,927,626 Pieces |
Production Hrs. Annual | 7,488 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $798,606 | 11,189,720 | kWh | $0.07 |
Electricity Demand | $194,499 | 21,141 | kW-months/year | $9.20 |
Electricity Fees | $1,968 | - | $ | - |
Natural Gas | $24,246 | 3,276 | MMBtu | $7.40 |
TOTAL ENERGY COSTS | $1,052,700 | |||
RECOMMENDED SAVINGS* | $76,266 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $56,442 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $5,498 Cost: $30 |
- | - | - | - | $5,498 | 743 | - | - |
- - kWh |
- - kW-months/year |
$5,498 743 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $26,162 Cost: $220 |
$26,162 | 366,408 | - | - | - | - | - | - |
$26,162 366,408 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $15,282 Cost: $1,568 |
$15,023 | 210,412 | $259 | 28 | - | - | - | - |
$15,023 210,412 kWh |
$259 28 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $19,256 Cost: $2,750 |
$19,256 | 269,694 | - | - | - | - | - | - |
$19,256 269,694 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,107 Cost: $725 |
$3,107 | 43,509 | - | - | - | - | - | - |
$3,107 43,509 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,749 Cost: $638 |
$1,449 | 20,300 | $300 | 33 | - | - | - | - |
$1,449 20,300 kWh |
$300 33 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,644 Cost: $3,840 |
$3,849 | 53,914 | $795 | 86 | - | - | - | - |
$3,849 53,914 kWh |
$795 86 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.4145 USE MAGNETIC TECHNOLOGY TO TREAT WATER |
Savings: $300 Cost: $416 |
- | - | - | - | - | - | $300 | 69 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$300 69 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $268 Cost: $463 |
$268 | 3,744 | - | - | - | - | - | - |
$268 3,744 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $76,266 Cost: $10,650 |
$69,114 | 967,981 | $1,354 | 147 | $5,498 | 743 | $300 | 69 | $69,114 967,981 kWh |
$1,354 147 kW-months/year |
$5,498 743 MMBtu |
$300 69 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $56,442 Cost: $7,021 |
$49,590 | 694,543 | $1,354 | 147 | $5,498 | 743 | - | - | $49,590 694,543 kWh |
$1,354 147 kW-months/year |
$5,498 743 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||